Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.790 kW
11/04/2025 12:22 (1987 days) Production Consumption NET Usage
Now 3.199 kW 0.409 kW -2.790 kW
Today 10.397 kWh (0.838 kW) 4.553 kWh (0.367 kW) -5.844 kWh (-0.471 kW)
  - This Week 34.214 kWh (13.597 kWh/day) 44.982 kWh (17.877 kWh/day) 10.768 kWh (4.279 kWh/day)
  - This Month 51.152 kWh (14.546 kWh/day) 61.170 kWh (17.394 kWh/day) 10.018 kWh (2.849 kWh/day)
  - This Year 5.629 MWh (18.305 kWh/day) 6.394 MWh (20.791 kWh/day) 0.764 MWh (2.486 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.080 MWh (17.650 kW/day) 38.346 MWh (19.293 kW/day) 3.266 MWh (1.643 kW/day)
Lifetime Since Install 35.114 MWh 38.926 MWh 3.812 MWh
Voltage/Current 250.3 V / 12.8 A 250.2 V / 1.6 A 250.3 V / -11.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/27/2020 23:25 (14.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.445 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.291 2.152 2.171 12.078 0.000 kW
2.070 kWh
0.000 kW
12.418 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.285 2.070 2.094 11.741
03 - 202224****** IQ7+M [5] VCOP 0.000 0.288 2.082 2.113 11.827
04 - 202232****** IQ7+ [5] VCOP 0.000 0.288 2.110 2.126 11.867
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.921 1.998 11.046
06 - 202245****** IQ7+M [5] VCOP 0.000 0.285 2.083 2.106 11.792
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.916 1.975 10.880 0.000 kW
1.973 kWh
0.000 kW
9.865 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.992 2.036 11.146
09 - 202217****** IQ7+ [5] VCOP 0.000 0.289 1.940 2.010 11.006
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 2.006 2.053 11.244
11 - 202224****** IQ7+M [5] VCOP 0.000 0.289 2.011 2.050 11.221
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.255 2.077 2.020 11.675 0.000 kW
2.040 kWh
0.000 kW
8.161 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.255 1.990 1.943 11.356
14 - 202216****** IQ7+ [5] VCOP 0.000 0.253 2.066 2.016 11.704
15 - 202245****** IQ7+M [5] VCOP 0.000 0.248 2.029 1.978 11.524
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.23 V Current/Power 166.26 A (8.851 kW)
Remain Capacity/Energy 553.5 Ah (28.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 95.9 % State Of Health 96.2 %
Run Time 8m to full Report Date 2020-07-27 23:12
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.52 A (-27 W) Runtime 14d 18h 48m to empty
Remain Capacity/Energy 184.5 Ah (9.4 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 95.9 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-07-27 23:12
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.323 V 3.323 V 3.324 V 3.325 V 3.325 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.328 V 3.328 V 3.329 V 3.330 V 3.331 V 3.331 V 3.331 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -