Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.452 kW
11/04/2025 13:52 (1987 days) Production Consumption NET Usage
Now 2.778 kW 0.326 kW -2.452 kW
Today 14.961 kWh (1.076 kW) 5.061 kWh (0.364 kW) -9.900 kWh (-0.712 kW)
  - This Week 38.778 kWh (15.037 kWh/day) 45.490 kWh (17.640 kWh/day) 6.712 kWh (2.603 kWh/day)
  - This Month 55.716 kWh (15.567 kWh/day) 61.678 kWh (17.233 kWh/day) 5.962 kWh (1.666 kWh/day)
  - This Year 5.634 MWh (18.316 kWh/day) 6.394 MWh (20.788 kWh/day) 0.760 MWh (2.472 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.085 MWh (17.652 kW/day) 38.347 MWh (19.293 kW/day) 3.262 MWh (1.641 kW/day)
Lifetime Since Install 35.118 MWh 38.927 MWh 3.808 MWh
Voltage/Current 251.0 V / 11.1 A 251.0 V / 1.3 A 251.0 V / -9.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/29/2020 23:23 (13.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.985 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.127 1.798 11.883 0.000 kW
2.054 kWh
0.000 kW
12.324 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.052 1.729 11.522
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.069 1.742 11.617
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.092 1.764 11.695
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.924 1.589 10.822
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.062 1.739 11.573
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.923 1.571 10.721 0.000 kW
1.987 kWh
0.000 kW
9.934 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.011 1.611 10.936
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.948 1.585 10.831
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.021 1.628 11.043
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.031 1.629 11.012
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.283 1.969 1.846 11.621 0.000 kW
1.932 kWh
0.000 kW
7.726 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.281 1.864 1.793 11.324
14 - 202216****** IQ7+ [5] VCOP 0.000 0.282 1.963 1.838 11.643
15 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.930 1.804 11.463
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.17 V Current/Power 166.06 A (8.830 kW)
Remain Capacity/Energy 475.5 Ah (24.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 82.4 % State Of Health 96.2 %
Run Time 36m to full Report Date 2020-07-29 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.17 V Cell (MIN/MAX) 3.318 V / 3.327 V (0.009 V)
Current/Power -0.52 A (-27 W) Runtime 12d 19h 10m to empty
Remain Capacity/Energy 158.5 Ah (8.1 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 82.4 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-07-29 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.319 V 3.319 V 3.320 V 3.321 V 3.321 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.324 V 3.325 V 3.326 V 3.326 V 3.327 V 3.327 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -