Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.595 kW
11/04/2025 10:34 (1987 days) Production Consumption NET Usage
Now 2.877 kW 0.282 kW -2.595 kW
Today 4.745 kWh (0.448 kW) 3.747 kWh (0.354 kW) -0.998 kWh (-0.094 kW)
  - This Week 28.562 kWh (11.702 kWh/day) 44.176 kWh (18.099 kWh/day) 15.614 kWh (6.397 kWh/day)
  - This Month 45.500 kWh (13.222 kWh/day) 60.364 kWh (17.542 kWh/day) 14.864 kWh (4.319 kWh/day)
  - This Year 5.623 MWh (18.291 kWh/day) 6.393 MWh (20.793 kWh/day) 0.769 MWh (2.502 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.074 MWh (17.648 kW/day) 38.345 MWh (19.294 kW/day) 3.271 MWh (1.646 kW/day)
Lifetime Since Install 35.108 MWh 38.925 MWh 3.817 MWh
Voltage/Current 249.7 V / 11.5 A 249.6 V / 1.1 A 249.6 V / -10.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/30/2020 23:14 (13.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.405 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.544 2.127 12.541 0.000 kW
1.495 kWh
0.000 kW
8.968 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.493 2.052 12.146
03 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.511 2.069 12.247
04 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.520 2.092 12.343
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.405 1.924 11.444
06 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.495 2.062 12.202
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.288 1.372 1.923 11.329 0.000 kW
1.378 kWh
0.000 kW
6.891 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.367 2.011 11.639
09 - 202217****** IQ7+ [5] VCOP 0.000 0.287 1.381 1.948 11.461
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.391 2.021 11.740
11 - 202224****** IQ7+M [5] VCOP 0.000 0.286 1.380 2.031 11.729
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.264 1.644 1.969 12.069 0.000 kW
1.636 kWh
0.000 kW
6.546 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.261 1.634 1.864 11.677
14 - 202216****** IQ7+ [5] VCOP 0.000 0.263 1.645 1.963 12.076
15 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.622 1.930 11.882
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.