Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.730 kW
11/04/2025 13:20 (1987 days) Production Consumption NET Usage
Now 3.003 kW 0.273 kW -2.730 kW
Today 13.399 kWh (1.003 kW) 4.901 kWh (0.367 kW) -8.498 kWh (-0.636 kW)
  - This Week 37.216 kWh (14.559 kWh/day) 45.330 kWh (17.733 kWh/day) 8.114 kWh (3.174 kWh/day)
  - This Month 54.154 kWh (15.226 kWh/day) 61.518 kWh (17.297 kWh/day) 7.364 kWh (2.071 kWh/day)
  - This Year 5.632 MWh (18.312 kWh/day) 6.394 MWh (20.789 kWh/day) 0.762 MWh (2.477 kWh/day)
Yesterday 6.646 kWh (0.277 kW) 14.112 kWh (0.588 kW) 7.466 kWh (0.311 kW)
Last 7 Days 74.080 kWh (10.584 kWh/day) 110.927 kWh (15.848 kWh/day) 36.847 kWh (5.264 kWh/day)
Last 30 Days 425.690 kWh (14.190 kWh/day) 478.568 kWh (15.953 kWh/day) 52.878 kWh (1.763 kWh/day)
Last One Year 6.195 MWh (16.972 kWh/day) 7.436 MWh (20.373 kWh/day) 1.241 MWh (3.401 kWh/day)
Lifetime Since PTO 35.083 MWh (17.651 kW/day) 38.347 MWh (19.293 kW/day) 3.264 MWh (1.642 kW/day)
Lifetime Since Install 35.117 MWh 38.927 MWh 3.810 MWh
Voltage/Current 250.2 V / 12.0 A 250.2 V / 1.1 A 250.2 V / -10.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/06/2020 23:07 (13.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.316 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.129 2.119 10.749 0.000 kW
1.118 kWh
0.000 kW
6.709 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.113 2.044 10.442
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.132 2.074 10.595
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.123 2.097 10.660
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.102 1.923 9.992
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.109 2.044 10.467
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.091 1.966 9.936 0.000 kW
1.098 kWh
0.000 kW
5.492 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.095 1.992 10.258
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.100 1.972 10.038
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.108 2.014 10.345
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.099 2.011 10.326
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.267 1.025 2.017 9.990 0.000 kW
1.029 kWh
0.000 kW
4.115 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.269 1.019 1.937 9.575
14 - 202216****** IQ7+ [5] VCOP 0.000 0.270 1.043 2.012 10.023
15 - 202245****** IQ7+M [5] VCOP 0.000 0.269 1.028 1.980 9.865
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.86 A (10.361 kW)
Remain Capacity/Energy 573.0 Ah (29.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.3 % State Of Health 96.2 %
Run Time 1m to full Report Date 2020-08-06 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.