Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.761 kW
09/14/2025 18:02 (1936 days) Production Consumption NET Usage
Now 0.185 kW 4.946 kW 4.761 kW
Today 23.091 kWh (1.278 kW) 24.354 kWh (1.348 kW) 1.263 kWh (0.070 kW)
  - This Week 23.091 kWh (30.681 kWh/day) 24.354 kWh (32.359 kWh/day) 1.263 kWh (1.678 kWh/day)
  - This Month 308.860 kWh (22.460 kWh/day) 328.911 kWh (23.918 kWh/day) 20.051 kWh (1.458 kWh/day)
  - This Year 4.816 MWh (18.758 kWh/day) 5.500 MWh (21.420 kWh/day) 0.683 MWh (2.662 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.267 MWh (17.693 kW/day) 37.452 MWh (19.337 kW/day) 3.185 MWh (1.644 kW/day)
Lifetime Since Install 34.301 MWh 38.032 MWh 3.731 MWh
Voltage/Current 247.0 V / 0.7 A 246.9 V / 20.0 A 246.9 V / 19.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/10/2020 22:25 (13.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.433 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.082 0.309 2.186 11.790 0.000 kW
0.305 kWh
0.000 kW
1.831 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.082 0.304 2.156 11.528
03 - 202224****** IQ7+M [5] VCOP 0.000 0.083 0.311 2.187 11.612
04 - 202232****** IQ7+ [5] VCOP 0.000 0.082 0.305 2.190 11.615
05 - 202244****** IQ7+M [5] VCOP 0.000 0.079 0.299 2.091 10.959
06 - 202245****** IQ7+M [5] VCOP 0.000 0.080 0.303 2.161 11.572
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.071 0.271 1.979 10.484 0.000 kW
0.273 kWh
0.000 kW
1.367 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.072 0.271 2.076 10.808
09 - 202217****** IQ7+ [5] VCOP 0.000 0.073 0.274 2.021 10.660
10 - 202244****** IQ7+M [5] VCOP 0.000 0.072 0.277 2.089 10.895
11 - 202224****** IQ7+M [5] VCOP 0.000 0.073 0.274 2.098 10.869
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.083 0.305 1.983 11.265 0.000 kW
0.309 kWh
0.000 kW
1.234 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.084 0.307 1.903 11.041
14 - 202216****** IQ7+ [5] VCOP 0.000 0.084 0.314 1.996 11.347
15 - 202245****** IQ7+M [5] VCOP 0.000 0.083 0.309 1.967 11.174
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.25 V Current/Power 166.29 A (8.855 kW)
Remain Capacity/Energy 566.7 Ah (29.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.2 % State Of Health 96.2 %
Run Time 3m to full Report Date 2020-07-10 23:40
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.25 V Cell (MIN/MAX) 3.323 V / 3.332 V (0.009 V)
Current/Power -0.57 A (-30 W) Runtime 13d 21h 9m to empty
Remain Capacity/Energy 188.9 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.2 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-10 23:40
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.323 V 3.323 V 3.324 V 3.324 V 3.326 V 3.326 V 3.326 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.329 V 3.328 V 3.329 V 3.329 V 3.330 V 3.332 V 3.332 V 3.332 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -