Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.274 kW
02/02/2026 23:24 (2078 days) Production Consumption NET Usage
Now 0.000 kW 0.274 kW 0.274 kW
Today 20.377 kWh (0.870 kW) 14.827 kWh (0.633 kW) -5.550 kWh (-0.237 kW)
  - This Week 42.561 kWh (21.536 kWh/day) 71.713 kWh (36.288 kWh/day) 29.152 kWh (14.751 kWh/day)
  - This Month 42.561 kWh (21.536 kWh/day) 71.713 kWh (36.288 kWh/day) 29.152 kWh (14.751 kWh/day)
  - This Year 0.288 MWh (8.733 kWh/day) 0.655 MWh (19.860 kWh/day) 0.367 MWh (11.127 kWh/day)
Yesterday 22.184 kWh (0.924 kW) 56.886 kWh (2.369 kW) 34.702 kWh (1.445 kW)
Last 7 Days 82.057 kWh (13.622 kWh/day) 138.390 kWh (22.973 kWh/day) 56.333 kWh (9.351 kWh/day)
Last 30 Days 242.585 kWh (8.358 kWh/day) 598.879 kWh (20.634 kWh/day) 356.294 kWh (12.276 kWh/day)
Last One Year 6.090 MWh (16.730 kWh/day) 7.535 MWh (20.699 kWh/day) 1.445 MWh (3.969 kWh/day)
Lifetime Since PTO 35.854 MWh (17.254 kW/day) 40.166 MWh (19.329 kW/day) 4.313 MWh (2.075 kW/day)
Lifetime Since Install 35.888 MWh 40.746 MWh 4.859 MWh
Voltage/Current 250.6 V / 0.0 A 250.7 V / 1.1 A 250.7 V / 1.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/09/2020 20:58 (8.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.535 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.127 0.325 0.369 3.935 0.000 kW
0.323 kWh
0.000 kW
1.940 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.139 0.315 0.365 3.819
03 - 202224****** IQ7+M [0] ---- 0.000 0.142 0.326 0.377 3.782
04 - 202232****** IQ7+ [0] ---- 0.000 0.115 0.308 0.373 3.610
05 - 202244****** IQ7+M [0] ---- 0.000 0.162 0.332 0.376 4.090
06 - 202245****** IQ7+M [0] ---- 0.000 0.171 0.334 0.365 4.064
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.200 0.342 0.434 4.873 0.000 kW
0.288 kWh
0.000 kW
1.441 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.061 0.052 0.433 4.437
09 - 202217****** IQ7+ [0] ---- 0.000 0.207 0.354 0.463 5.206
10 - 202244****** IQ7+M [0] ---- 0.000 0.200 0.351 0.461 5.177
11 - 202224****** IQ7+M [0] ---- 0.000 0.201 0.343 0.454 4.870
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.101 0.284 0.256 2.013 0.000 kW
0.288 kWh
0.000 kW
1.154 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.105 0.290 0.259 2.203
14 - 202216****** IQ7+ [0] V--- 0.000 0.102 0.294 0.262 2.197
15 - 202245****** IQ7+M [0] ---- 0.000 0.103 0.285 0.257 2.144
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.49 V Current/Power 163.92 A (8.605 kW)
Remain Capacity/Energy 334.2 Ah (17.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 56.5 % State Of Health 98.5 %
Run Time 1h 33m to full Report Date 2020-12-09 20:48
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.49 V Cell (MIN/MAX) 3.276 V / 3.285 V (0.009 V)
Current/Power -0.55 A (-28 W) Runtime 8d 10h 32m to empty
Remain Capacity/Energy 111.4 Ah (5.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 56.5 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-09 20:48
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.276 V 3.276 V 3.277 V 3.278 V 3.279 V 3.278 V 3.280 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.283 V 3.282 V 3.283 V 3.284 V 3.285 V 3.285 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -