Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.363 kW
07/04/2025 07:56 (1864 days) Production Consumption NET Usage
Now 0.771 kW 0.408 kW -0.363 kW
Today 0.842 kWh (0.106 kW) 3.062 kWh (0.386 kW) 2.220 kWh (0.280 kW)
  - This Week 123.941 kWh (23.250 kWh/day) 159.435 kWh (29.909 kWh/day) 35.494 kWh (6.658 kWh/day)
  - This Month 66.655 kWh (20.007 kWh/day) 91.753 kWh (27.541 kWh/day) 25.098 kWh (7.534 kWh/day)
  - This Year 3.096 MWh (16.798 kWh/day) 3.219 MWh (17.463 kWh/day) 0.123 MWh (0.665 kWh/day)
Yesterday 24.042 kWh (1.001 kW) 27.565 kWh (1.148 kW) 3.523 kWh (0.147 kW)
Last 7 Days 156.185 kWh (22.312 kWh/day) 227.613 kWh (32.515 kWh/day) 71.428 kWh (10.204 kWh/day)
Last 30 Days 613.088 kWh (20.436 kWh/day) 820.402 kWh (27.346 kWh/day) 207.314 kWh (6.910 kWh/day)
Last One Year 6.311 MWh (17.291 kWh/day) 6.385 MWh (17.493 kWh/day) 0.074 MWh (0.202 kWh/day)
Lifetime Since PTO 32.547 MWh (17.458 kW/day) 35.171 MWh (18.865 kW/day) 2.624 MWh (1.407 kW/day)
Lifetime Since Install 32.581 MWh 35.751 MWh 3.170 MWh
Voltage/Current 249.2 V / 3.1 A 249.2 V / 1.6 A 249.2 V / -1.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/04/2020 20:22 (14.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.177 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.809 1.399 11.433 0.000 kW
1.736 kWh
0.000 kW
10.416 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.746 1.336 11.107
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.741 1.333 11.124
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.754 1.335 11.145
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.607 1.252 10.380
06 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.759 1.357 11.116
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.604 1.257 10.139 0.000 kW
1.611 kWh
0.000 kW
8.057 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.608 1.272 10.436
09 - 202217****** IQ7+ [5] VCOP 0.000 0.292 1.608 1.277 10.388
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.623 1.286 10.546
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 1.613 1.285 10.532
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.270 1.936 1.415 11.403 0.000 kW
1.926 kWh
0.000 kW
7.704 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.272 1.932 1.361 11.094
14 - 202216****** IQ7+ [5] VCOP 0.000 0.271 1.937 1.417 11.374
15 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.900 1.394 11.211
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.03 V Current/Power 175.11 A (9.812 kW)
Remain Capacity/Energy 571.5 Ah (29.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.0 % State Of Health 96.2 %
Run Time 1m to full Report Date 2020-06-04 20:12
voltag, current for each battery pack voltage, current, and SOC

Voltage 56.03 V Cell (MIN/MAX) 3.494 V / 3.507 V (0.013 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.5 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.0 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-04 20:12
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.500 V 3.494 V 3.503 V 3.502 V 3.501 V 3.502 V 3.504 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.500 V 3.502 V 3.502 V 3.503 V 3.505 V 3.504 V 3.504 V 3.507 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -