Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.616 kW
09/14/2025 15:41 (1936 days) Production Consumption NET Usage
Now 3.075 kW 2.459 kW -0.616 kW
Today 20.278 kWh (1.291 kW) 10.454 kWh (0.665 kW) -9.824 kWh (-0.625 kW)
  - This Week 20.278 kWh (30.976 kWh/day) 10.454 kWh (15.969 kWh/day) -9.824 kWh (-15.007 kWh/day)
  - This Month 306.047 kWh (22.415 kWh/day) 315.011 kWh (23.071 kWh/day) 8.964 kWh (0.657 kWh/day)
  - This Year 4.813 MWh (18.754 kWh/day) 5.486 MWh (21.374 kWh/day) 0.672 MWh (2.620 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.264 MWh (17.693 kW/day) 37.438 MWh (19.331 kW/day) 3.173 MWh (1.639 kW/day)
Lifetime Since Install 34.298 MWh 38.018 MWh 3.720 MWh
Voltage/Current 248.2 V / 12.4 A 248.2 V / 9.9 A 248.2 V / -2.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/26/2020 23:47 (13.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.239 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.815 1.656 11.889 0.000 kW
1.782 kWh
0.000 kW
10.693 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.784 1.622 11.681
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.824 1.652 11.908
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.839 1.648 11.949
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.697 1.545 11.236
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.734 1.584 11.497
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.726 1.585 11.483 0.000 kW
1.729 kWh
0.000 kW
8.645 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.686 1.563 11.578
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.725 1.594 11.477
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.756 1.615 11.764
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.752 1.616 11.816
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.742 1.496 10.450 0.000 kW
1.725 kWh
0.000 kW
6.901 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.261 1.715 1.469 10.055
14 - 202216****** IQ7+ [5] VCOP 0.000 0.260 1.736 1.495 10.472
15 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.708 1.469 10.305
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 50.91 V Current/Power 159.00 A (8.095 kW)
Remain Capacity/Energy 57.6 Ah (2.9 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 10.0 % State Of Health 96.2 %
Run Time 3h 16m to full Report Date 2020-08-26 23:47
voltag, current for each battery pack voltage, current, and SOC

Voltage 50.91 V Cell (MIN/MAX) 3.177 V / 3.187 V (0.010 V)
Current/Power -0.57 A (-28 W) Runtime 1d 9h 51m to empty
Remain Capacity/Energy 19.2 Ah (1.0 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 10.0 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-26 23:47
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.178 V 3.177 V 3.179 V 3.178 V 3.182 V 3.180 V 3.181 V 3.183 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.181 V 3.182 V 3.184 V 3.182 V 3.185 V 3.184 V 3.186 V 3.187 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -