Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 3.756 kW
09/14/2025 16:09 (1936 days) Production Consumption NET Usage
Now 2.868 kW 6.624 kW 3.756 kW
Today 21.473 kWh (1.328 kW) 11.598 kWh (0.717 kW) -9.875 kWh (-0.611 kW)
  - This Week 21.473 kWh (31.862 kWh/day) 11.598 kWh (17.209 kWh/day) -9.875 kWh (-14.653 kWh/day)
  - This Month 307.242 kWh (22.470 kWh/day) 316.155 kWh (23.122 kWh/day) 8.913 kWh (0.652 kWh/day)
  - This Year 4.815 MWh (18.758 kWh/day) 5.487 MWh (21.377 kWh/day) 0.672 MWh (2.619 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.265 MWh (17.693 kW/day) 37.439 MWh (19.332 kW/day) 3.173 MWh (1.639 kW/day)
Lifetime Since Install 34.299 MWh 38.019 MWh 3.719 MWh
Voltage/Current 247.8 V / 11.6 A 247.6 V / 26.7 A 247.7 V / 15.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/07/2020 23:25 (12.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.265 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.278 1.600 1.541 9.371 0.000 kW
1.584 kWh
0.000 kW
9.504 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.592 1.529 9.262
03 - 202224****** IQ7+M [5] VCOP 0.000 0.281 1.630 1.564 9.424
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 1.634 1.566 9.379
05 - 202244****** IQ7+M [5] VCOP 0.000 0.280 1.528 1.458 8.991
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.520 1.458 9.031
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.574 1.486 9.188 0.000 kW
1.562 kWh
0.000 kW
7.811 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.483 1.420 9.033
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.579 1.482 9.141
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.591 1.523 9.374
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.582 1.517 9.343
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.216 1.489 1.461 8.213 0.000 kW
1.488 kWh
0.000 kW
5.950 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.215 1.480 1.448 8.063
14 - 202216****** IQ7+ [5] VCOP 0.000 0.213 1.499 1.464 8.257
15 - 202245****** IQ7+M [5] VCOP 0.000 0.210 1.483 1.442 8.124
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.95 A (10.368 kW)
Remain Capacity/Energy 585.0 Ah (30.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.0 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-09-07 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.62 V Cell (MIN/MAX) 3.587 V / 3.607 V (0.020 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 195.0 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.0 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-07 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.600 V 3.598 V 3.599 V 3.599 V 3.599 V 3.596 V 3.605 V 3.602 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.598 V 3.600 V 3.600 V 3.587 V 3.605 V 3.606 V 3.607 V 3.607 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -