Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.195 kW
09/14/2025 12:25 (1936 days) Production Consumption NET Usage
Now 3.634 kW 0.439 kW -3.195 kW
Today 9.636 kWh (0.774 kW) 6.473 kWh (0.520 kW) -3.163 kWh (-0.254 kW)
  - This Week 9.636 kWh (18.587 kWh/day) 6.473 kWh (12.486 kWh/day) -3.163 kWh (-6.101 kWh/day)
  - This Month 295.405 kWh (21.853 kWh/day) 311.030 kWh (23.009 kWh/day) 15.625 kWh (1.156 kWh/day)
  - This Year 4.803 MWh (18.723 kWh/day) 5.482 MWh (21.370 kWh/day) 0.679 MWh (2.647 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.254 MWh (17.688 kW/day) 37.434 MWh (19.330 kW/day) 3.180 MWh (1.642 kW/day)
Lifetime Since Install 34.288 MWh 38.014 MWh 3.726 MWh
Voltage/Current 251.2 V / 14.5 A 251.1 V / 1.7 A 251.1 V / -12.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/24/2020 23:03 (11.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.478 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.154 0.761 1.739 11.675 0.000 kW
0.810 kWh
0.000 kW
4.861 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.162 0.855 1.720 11.576
03 - 202224****** IQ7+M [5] VCOP 0.000 0.163 0.789 1.743 11.755
04 - 202232****** IQ7+ [5] VCOP 0.000 0.173 0.784 1.730 11.683
05 - 202244****** IQ7+M [5] VCOP 0.000 0.152 0.825 1.687 11.352
06 - 202245****** IQ7+M [5] VCOP 0.000 0.162 0.847 1.669 11.273
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.161 0.826 1.823 12.111 0.000 kW
0.755 kWh
0.000 kW
3.774 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.147 0.697 1.695 11.459
09 - 202217****** IQ7+ [5] VCOP 0.000 0.161 0.772 1.841 12.175
10 - 202244****** IQ7+M [5] VCOP 0.000 0.163 0.739 1.858 12.301
11 - 202224****** IQ7+M [5] VCOP 0.000 0.161 0.740 1.851 12.240
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.143 0.715 1.316 9.183 0.000 kW
0.711 kWh
0.000 kW
2.843 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.142 0.705 1.286 8.969
14 - 202216****** IQ7+ [5] VCOP 0.000 0.143 0.687 1.313 9.220
15 - 202245****** IQ7+M [5] VCOP 0.000 0.143 0.736 1.289 9.065
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.03 A (9.806 kW)
Remain Capacity/Energy 572.1 Ah (29.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 96.8 % State Of Health 98.5 %
Run Time 6m to full Report Date 2020-09-24 23:15
voltag, current for each battery pack voltage, current, and SOC

Voltage 56.03 V Cell (MIN/MAX) 3.495 V / 3.508 V (0.013 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.7 Ah (9.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 96.8 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-24 23:15
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.500 V 3.495 V 3.500 V 3.502 V 3.500 V 3.497 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.499 V 3.501 V 3.500 V 3.502 V 3.503 V 3.506 V 3.507 V 3.508 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -