Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.782 kW
07/03/2025 21:35 (1863 days) Production Consumption NET Usage
Now 0.000 kW 0.782 kW 0.782 kW
Today 24.042 kWh (1.112 kW) 25.085 kWh (1.160 kW) 1.043 kWh (0.048 kW)
  - This Week 123.099 kWh (25.122 kWh/day) 153.893 kWh (31.407 kWh/day) 30.794 kWh (6.285 kWh/day)
  - This Month 65.813 kWh (22.688 kWh/day) 86.211 kWh (29.720 kWh/day) 20.398 kWh (7.032 kWh/day)
  - This Year 3.096 MWh (16.833 kWh/day) 3.213 MWh (17.474 kWh/day) 0.118 MWh (0.641 kWh/day)
Yesterday 20.789 kWh (0.866 kW) 29.763 kWh (1.240 kW) 8.974 kWh (0.374 kW)
Last 7 Days 143.248 kWh (20.464 kWh/day) 238.833 kWh (34.120 kWh/day) 95.585 kWh (13.655 kWh/day)
Last 30 Days 620.761 kWh (20.692 kWh/day) 804.732 kWh (26.825 kWh/day) 183.971 kWh (6.132 kWh/day)
Last One Year 6.324 MWh (17.327 kWh/day) 6.396 MWh (17.523 kWh/day) 0.072 MWh (0.196 kWh/day)
Lifetime Since PTO 32.546 MWh (17.461 kW/day) 35.165 MWh (18.867 kW/day) 2.619 MWh (1.405 kW/day)
Lifetime Since Install 32.580 MWh 35.745 MWh 3.165 MWh
Voltage/Current 249.8 V / 0.0 A 249.8 V / 3.1 A 249.8 V / 3.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/17/2020 22:53 (13.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.107 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.293 0.996 1.653 11.642 0.000 kW
0.990 kWh
0.000 kW
5.942 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.291 0.984 1.638 11.345
03 - 202224****** IQ7+M [0] ---- 0.000 0.292 1.003 1.667 11.388
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 0.993 1.657 11.412
05 - 202244****** IQ7+M [0] ---- 0.000 0.292 0.983 1.617 10.636
06 - 202245****** IQ7+M [0] ---- 0.000 0.290 0.982 1.642 11.429
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.294 0.944 1.543 10.352 0.000 kW
0.972 kWh
0.000 kW
4.860 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 0.976 1.634 10.819
09 - 202217****** IQ7+ [0] ---- 0.000 0.292 0.954 1.596 10.585
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 0.990 1.653 10.912
11 - 202224****** IQ7+M [0] ---- 0.000 0.294 0.995 1.646 10.905
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.246 0.831 1.444 11.448 0.000 kW
0.826 kWh
0.000 kW
3.305 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.249 0.803 1.395 11.056
14 - 202216****** IQ7+ [0] ---- 0.000 0.248 0.843 1.465 11.438
15 - 202245****** IQ7+M [0] ---- 0.000 0.241 0.829 1.444 11.259
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.44 V Current/Power 163.77 A (8.587 kW)
Remain Capacity/Energy 288.3 Ah (14.8 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 49.9 % State Of Health 96.2 %
Run Time 1h 45m to full Report Date 2020-07-17 23:18
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.44 V Cell (MIN/MAX) 3.272 V / 3.282 V (0.010 V)
Current/Power -0.57 A (-29 W) Runtime 7d 1h 29m to empty
Remain Capacity/Energy 96.1 Ah (4.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 49.9 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-17 23:18
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.272 V 3.272 V 3.274 V 3.274 V 3.275 V 3.276 V 3.276 V 3.277 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.278 V 3.278 V 3.278 V 3.278 V 3.280 V 3.280 V 3.281 V 3.282 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -