Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.407 kW
03/21/2026 19:12 (2124 days) Production Consumption NET Usage
Now 0.000 kW 0.407 kW 0.407 kW
Today 24.582 kWh (1.279 kW) 11.582 kWh (0.603 kW) -13.000 kWh (-0.676 kW)
  - This Week 138.319 kWh (20.340 kWh/day) 129.898 kWh (19.101 kWh/day) -8.421 kWh (-1.238 kWh/day)
  - This Month 373.040 kWh (17.934 kWh/day) 333.925 kWh (16.054 kWh/day) -39.115 kWh (-1.880 kWh/day)
  - This Year 1.007 MWh (12.618 kWh/day) 1.434 MWh (17.967 kWh/day) 0.427 MWh (5.348 kWh/day)
Yesterday 19.934 kWh (0.831 kW) 13.045 kWh (0.544 kW) -6.889 kWh (-0.287 kW)
Last 7 Days 139.829 kWh (19.976 kWh/day) 132.904 kWh (18.986 kWh/day) -6.925 kWh (-0.989 kWh/day)
Last 30 Days (02/19/2026) 467.704 kWh (15.590 kWh/day) 488.242 kWh (16.275 kWh/day) 20.538 kWh (0.685 kWh/day)
Last One Year 6.078 MWh (16.652 kWh/day) 7.893 MWh (21.623 kWh/day) 1.815 MWh (4.972 kWh/day)
Lifetime Since PTO 36.573 MWh (17.212 kW/day) 40.945 MWh (19.270 kW/day) 4.372 MWh (2.058 kW/day)
Lifetime Since Install 36.607 MWh 41.524 MWh 4.918 MWh
Voltage/Current 249.4 V / 0.0 A 249.5 V / 1.6 A 249.5 V / 1.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/17/2021 23:20 (12.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.560 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.147 1.066 6.725 0.000 kW
1.117 kWh
0.000 kW
6.703 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.109 1.025 6.533
03 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.142 1.074 6.738
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.137 1.098 6.766
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.061 0.980 6.305
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.106 1.001 6.431
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 1.057 0.978 6.413 0.000 kW
1.061 kWh
0.000 kW
5.307 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.035 0.950 6.346
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.070 0.990 6.421
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.079 0.996 6.542
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.067 0.987 6.516
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.297 1.143 1.244 6.354 0.000 kW
1.137 kWh
0.000 kW
4.550 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.294 1.129 1.238 6.237
14 - 202216****** IQ7+ [0] ---- 0.000 0.294 1.147 1.246 6.401
15 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.131 1.232 6.310
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.19 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 481.8 Ah (24.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 80.3 % State Of Health 100.0 %
Run Time 16d 17h 29m to empty Report Date 2021-04-17 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.