Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.719 kW
07/03/2025 13:52 (1863 days) Production Consumption NET Usage
Now 1.416 kW 0.697 kW -0.719 kW
Today 15.757 kWh (1.133 kW) 12.181 kWh (0.876 kW) -3.576 kWh (-0.257 kW)
  - This Week 114.814 kWh (25.078 kWh/day) 140.989 kWh (30.795 kWh/day) 26.175 kWh (5.717 kWh/day)
  - This Month 57.528 kWh (22.305 kWh/day) 73.307 kWh (28.424 kWh/day) 15.779 kWh (6.118 kWh/day)
  - This Year 3.087 MWh (16.817 kWh/day) 3.201 MWh (17.434 kWh/day) 0.113 MWh (0.617 kWh/day)
Yesterday 20.789 kWh (0.866 kW) 29.763 kWh (1.240 kW) 8.974 kWh (0.374 kW)
Last 7 Days 143.248 kWh (20.464 kWh/day) 238.833 kWh (34.120 kWh/day) 95.585 kWh (13.655 kWh/day)
Last 30 Days 620.761 kWh (20.692 kWh/day) 804.732 kWh (26.825 kWh/day) 183.971 kWh (6.132 kWh/day)
Last One Year 6.324 MWh (17.327 kWh/day) 6.396 MWh (17.523 kWh/day) 0.072 MWh (0.196 kWh/day)
Lifetime Since PTO 32.538 MWh (17.460 kW/day) 35.153 MWh (18.863 kW/day) 2.614 MWh (1.403 kW/day)
Lifetime Since Install 32.572 MWh 35.732 MWh 3.160 MWh
Voltage/Current 246.6 V / 5.7 A 246.6 V / 2.8 A 246.6 V / -2.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/19/2020 23:17 (13.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.851 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.260 0.917 1.960 9.115 0.000 kW
0.912 kWh
0.000 kW
5.471 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.257 0.907 1.915 8.903
03 - 202224****** IQ7+M [5] VCOP 0.000 0.259 0.924 1.951 9.078
04 - 202232****** IQ7+ [5] VCOP 0.000 0.258 0.913 1.970 9.126
05 - 202244****** IQ7+M [5] VCOP 0.000 0.259 0.905 1.809 8.407
06 - 202245****** IQ7+M [5] VCOP 0.000 0.257 0.906 1.882 8.789
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.290 0.890 1.841 8.247 0.000 kW
0.931 kWh
0.000 kW
4.654 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.289 0.961 1.850 8.221
09 - 202217****** IQ7+ [5] VCOP 0.000 0.287 0.891 1.839 8.263
10 - 202244****** IQ7+M [5] VCOP 0.000 0.287 0.945 1.893 8.416
11 - 202224****** IQ7+M [5] VCOP 0.000 0.287 0.966 1.890 8.396
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.204 0.692 1.852 9.102 0.000 kW
0.682 kWh
0.000 kW
2.727 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.206 0.637 1.761 8.972
14 - 202216****** IQ7+ [5] VCOP 0.000 0.206 0.705 1.842 9.153
15 - 202245****** IQ7+M [5] VCOP 0.000 0.203 0.693 1.807 9.022
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.47 V Current/Power 163.88 A (8.599 kW)
Remain Capacity/Energy 325.8 Ah (16.7 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 56.4 % State Of Health 96.2 %
Run Time 1h 32m to full Report Date 2020-08-19 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.47 V Cell (MIN/MAX) 3.274 V / 3.284 V (0.010 V)
Current/Power -0.52 A (-27 W) Runtime 8d 18h 3m to empty
Remain Capacity/Energy 108.6 Ah (5.6 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 56.4 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-19 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.274 V 3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.280 V 3.281 V 3.282 V 3.282 V 3.283 V 3.284 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -