Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.488 kW
07/03/2025 14:36 (1863 days) Production Consumption NET Usage
Now 1.156 kW 0.668 kW -0.488 kW
Today 17.500 kWh (1.195 kW) 13.503 kWh (0.922 kW) -3.997 kWh (-0.273 kW)
  - This Week 116.557 kWh (25.288 kWh/day) 142.311 kWh (30.875 kWh/day) 25.754 kWh (5.588 kWh/day)
  - This Month 59.271 kWh (22.709 kWh/day) 74.629 kWh (28.594 kWh/day) 15.358 kWh (5.884 kWh/day)
  - This Year 3.089 MWh (16.824 kWh/day) 3.202 MWh (17.438 kWh/day) 0.113 MWh (0.615 kWh/day)
Yesterday 20.789 kWh (0.866 kW) 29.763 kWh (1.240 kW) 8.974 kWh (0.374 kW)
Last 7 Days 143.248 kWh (20.464 kWh/day) 238.833 kWh (34.120 kWh/day) 95.585 kWh (13.655 kWh/day)
Last 30 Days 620.761 kWh (20.692 kWh/day) 804.732 kWh (26.825 kWh/day) 183.971 kWh (6.132 kWh/day)
Last One Year 6.324 MWh (17.327 kWh/day) 6.396 MWh (17.523 kWh/day) 0.072 MWh (0.196 kWh/day)
Lifetime Since PTO 32.540 MWh (17.461 kW/day) 35.154 MWh (18.863 kW/day) 2.614 MWh (1.403 kW/day)
Lifetime Since Install 32.574 MWh 35.734 MWh 3.160 MWh
Voltage/Current 248.1 V / 4.7 A 248.2 V / 2.7 A 248.2 V / -2.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/22/2020 23:56 (13.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.667 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.602 1.889 10.448 0.000 kW
1.583 kWh
0.000 kW
9.500 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.580 1.857 10.237
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.603 1.893 10.439
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.600 1.897 10.489
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.542 1.762 9.759
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.573 1.826 10.078
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.531 1.817 9.825 0.000 kW
1.568 kWh
0.000 kW
7.840 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.583 1.816 9.891
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.529 1.822 9.815
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.592 1.863 10.065
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.604 1.862 10.079
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.236 1.342 1.700 9.724 0.000 kW
1.332 kWh
0.000 kW
5.327 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.236 1.312 1.639 9.381
14 - 202216****** IQ7+ [5] VCOP 0.000 0.237 1.347 1.699 9.749
15 - 202245****** IQ7+M [5] VCOP 0.000 0.234 1.325 1.669 9.592
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.39 V Current/Power 163.58 A (8.569 kW)
Remain Capacity/Energy 213.9 Ah (11.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 37.1 % State Of Health 96.2 %
Run Time 2h 13m to full Report Date 2020-08-22 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.39 V Cell (MIN/MAX) 3.268 V / 3.279 V (0.011 V)
Current/Power -0.52 A (-27 W) Runtime 5d 17h 54m to empty
Remain Capacity/Energy 71.3 Ah (3.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 37.1 % State Of Health 96.2 %
Temperature 26.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-22 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.268 V 3.268 V 3.271 V 3.271 V 3.272 V 3.271 V 3.273 V 3.274 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.275 V 3.274 V 3.275 V 3.275 V 3.277 V 3.277 V 3.278 V 3.279 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -