Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.706 kW
07/03/2025 13:12 (1863 days) Production Consumption NET Usage
Now 4.345 kW 0.639 kW -3.706 kW
Today 13.694 kWh (1.034 kW) 11.030 kWh (0.833 kW) -2.664 kWh (-0.201 kW)
  - This Week 112.751 kWh (24.776 kWh/day) 139.838 kWh (30.728 kWh/day) 27.087 kWh (5.952 kWh/day)
  - This Month 55.465 kWh (21.737 kWh/day) 72.156 kWh (28.279 kWh/day) 16.691 kWh (6.541 kWh/day)
  - This Year 3.085 MWh (16.808 kWh/day) 3.199 MWh (17.431 kWh/day) 0.114 MWh (0.622 kWh/day)
Yesterday 20.789 kWh (0.866 kW) 29.763 kWh (1.240 kW) 8.974 kWh (0.374 kW)
Last 7 Days 143.248 kWh (20.464 kWh/day) 238.833 kWh (34.120 kWh/day) 95.585 kWh (13.655 kWh/day)
Last 30 Days 620.761 kWh (20.692 kWh/day) 804.732 kWh (26.825 kWh/day) 183.971 kWh (6.132 kWh/day)
Last One Year 6.324 MWh (17.327 kWh/day) 6.396 MWh (17.523 kWh/day) 0.072 MWh (0.196 kWh/day)
Lifetime Since PTO 32.536 MWh (17.459 kW/day) 35.151 MWh (18.863 kW/day) 2.615 MWh (1.403 kW/day)
Lifetime Since Install 32.570 MWh 35.731 MWh 3.161 MWh
Voltage/Current 249.2 V / 17.4 A 249.2 V / 2.6 A 249.2 V / -14.9 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/26/2020 23:47 (13.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.239 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.815 1.656 11.889 0.000 kW
1.782 kWh
0.000 kW
10.693 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.784 1.622 11.681
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.824 1.652 11.908
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.839 1.648 11.949
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.697 1.545 11.236
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.734 1.584 11.497
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.726 1.585 11.483 0.000 kW
1.729 kWh
0.000 kW
8.645 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.686 1.563 11.578
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.725 1.594 11.477
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.756 1.615 11.764
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.752 1.616 11.816
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.742 1.496 10.450 0.000 kW
1.725 kWh
0.000 kW
6.901 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.261 1.715 1.469 10.055
14 - 202216****** IQ7+ [5] VCOP 0.000 0.260 1.736 1.495 10.472
15 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.708 1.469 10.305
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 50.91 V Current/Power 159.00 A (8.095 kW)
Remain Capacity/Energy 57.6 Ah (2.9 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 10.0 % State Of Health 96.2 %
Run Time 3h 16m to full Report Date 2020-08-26 23:47
voltag, current for each battery pack voltage, current, and SOC

Voltage 50.91 V Cell (MIN/MAX) 3.177 V / 3.187 V (0.010 V)
Current/Power -0.57 A (-28 W) Runtime 1d 9h 51m to empty
Remain Capacity/Energy 19.2 Ah (1.0 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 10.0 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-26 23:47
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.178 V 3.177 V 3.179 V 3.178 V 3.182 V 3.180 V 3.181 V 3.183 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.181 V 3.182 V 3.184 V 3.182 V 3.185 V 3.184 V 3.186 V 3.187 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -