Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.191 kW
05/14/2026 00:28 (2178 days) Production Consumption NET Usage
Now 0.317 kW 0.126 kW -0.191 kW
Today 0.154 kWh (0.317 kW) 0.240 kWh (0.493 kW) 0.086 kWh (0.177 kW)
  - This Week 107.455 kWh (26.727 kWh/day) 51.602 kWh (12.835 kWh/day) -55.853 kWh (-13.892 kWh/day)
  - This Month 325.530 kWh (25.002 kWh/day) 168.739 kWh (12.960 kWh/day) -156.791 kWh (-12.042 kWh/day)
  - This Year 2.279 MWh (17.129 kWh/day) 2.228 MWh (16.753 kWh/day) -0.050 MWh (-0.377 kWh/day)
Yesterday 25.506 kWh (1.062 kW) 14.443 kWh (0.601 kW) -11.063 kWh (-0.461 kW)
Last 7 Days 171.923 kWh (24.560 kWh/day) 125.531 kWh (17.933 kWh/day) -46.392 kWh (-6.627 kWh/day)
Last 30 Days (04/14/2026) 708.180 kWh (23.606 kWh/day) 433.706 kWh (14.457 kWh/day) -274.474 kWh (-9.149 kWh/day)
Last One Year 6.314 MWh (17.298 kWh/day) 7.793 MWh (21.350 kWh/day) 1.479 MWh (4.051 kWh/day)
Lifetime Since PTO 37.844 MWh (17.376 kW/day) 41.739 MWh (19.164 kW/day) 3.895 MWh (1.788 kW/day)
Lifetime Since Install 37.878 MWh 42.319 MWh 4.441 MWh
Voltage/Current 250.9 V / 1.3 A 250.8 V / 0.5 A 250.8 V / -0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/12/2021 20:16 (13.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.464 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.065 0.871 10.239 0.000 kW
1.049 kWh
0.000 kW
6.291 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.039 0.846 9.852
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.063 0.874 10.005
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.058 0.871 10.047
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.028 0.844 9.271
06 - 202245****** IQ7+M [0] ---- 0.000 0.301 1.039 0.849 9.918
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.299 1.005 0.839 9.232 0.000 kW
1.007 kWh
0.000 kW
5.037 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 0.999 0.837 9.301
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.009 0.846 9.341
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.014 0.852 9.436
11 - 202224****** IQ7+M [0] ---- 0.000 0.294 1.010 0.850 9.424
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.292 1.030 0.770 10.032 0.000 kW
1.034 kWh
0.000 kW
4.135 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.297 1.029 0.752 9.807
14 - 202216****** IQ7+ [0] ---- 0.000 0.296 1.045 0.787 10.039
15 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.031 0.775 9.970
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 445.8 Ah (22.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 74.3 % State Of Health 100.0 %
Run Time 12d 9h 12m to empty Report Date 2021-07-12 23:58
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.