Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.338 kW
06/29/2026 12:34 (2224 days) Production Consumption NET Usage
Now 4.254 kW 0.916 kW -3.338 kW
Today 11.942 kWh (0.950 kW) 8.379 kWh (0.666 kW) -3.563 kWh (-0.283 kW)
  - This Week 39.003 kWh (25.593 kWh/day) 36.688 kWh (24.074 kWh/day) -2.315 kWh (-1.519 kWh/day)
  - This Month 832.830 kWh (29.196 kWh/day) 679.384 kWh (23.817 kWh/day) -153.446 kWh (-5.379 kWh/day)
  - This Year 3.567 MWh (19.871 kWh/day) 3.249 MWh (18.100 kWh/day) -0.318 MWh (-1.771 kWh/day)
Yesterday 27.061 kWh (1.128 kW) 28.309 kWh (1.180 kW) 1.248 kWh (0.052 kW)
Last 7 Days 142.173 kWh (20.310 kWh/day) 173.163 kWh (24.738 kWh/day) 30.990 kWh (4.427 kWh/day)
Last 30 Days (05/30/2026) 879.814 kWh (29.327 kWh/day) 686.871 kWh (22.896 kWh/day) -192.943 kWh (-6.431 kWh/day)
Last One Year 6.698 MWh (18.351 kWh/day) 7.737 MWh (21.198 kWh/day) 1.039 MWh (2.847 kWh/day)
Lifetime Since PTO 39.133 MWh (17.592 kW/day) 42.760 MWh (19.222 kW/day) 3.627 MWh (1.631 kW/day)
Lifetime Since Install 39.167 MWh 43.340 MWh 4.173 MWh
Voltage/Current 250.0 V / 17.0 A 250.0 V / 3.7 A 250.0 V / -13.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/04/2021 23:31 (11.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.682 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.975 1.611 7.567 0.000 kW
1.928 kWh
0.000 kW
11.566 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.928 1.540 7.337
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.979 1.621 7.602
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.976 1.620 7.564
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.856 1.507 7.192
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.852 1.498 7.197
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.998 1.516 7.294 0.000 kW
2.000 kWh
0.000 kW
9.999 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.951 1.498 7.187
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.967 1.486 7.270
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 2.039 1.570 7.427
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.044 1.577 7.421
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.269 1.880 1.551 6.823 0.000 kW
1.779 kWh
0.000 kW
7.117 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.270 1.814 1.524 6.705
14 - 202216****** IQ7+ [5] VCOP 0.000 0.267 1.887 1.556 6.871
15 - 202245****** IQ7+M [5] VCOP 0.000 0.261 1.537 1.527 6.762
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 530.1 Ah (27.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.4 % State Of Health 100.0 %
Run Time 18d 9h 44m to empty Report Date 2021-09-04 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.