Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.487 kW
07/03/2025 07:58 (1863 days) Production Consumption NET Usage
Now 0.765 kW 0.278 kW -0.487 kW
Today 0.852 kWh (0.106 kW) 5.208 kWh (0.651 kW) 4.356 kWh (0.544 kW)
  - This Week 99.909 kWh (23.059 kWh/day) 134.016 kWh (30.932 kWh/day) 34.107 kWh (7.872 kWh/day)
  - This Month 42.623 kWh (18.266 kWh/day) 66.334 kWh (28.428 kWh/day) 23.711 kWh (10.161 kWh/day)
  - This Year 3.072 MWh (16.758 kWh/day) 3.194 MWh (17.420 kWh/day) 0.121 MWh (0.661 kWh/day)
Yesterday 20.789 kWh (0.866 kW) 29.763 kWh (1.240 kW) 8.974 kWh (0.374 kW)
Last 7 Days 143.248 kWh (20.464 kWh/day) 238.833 kWh (34.120 kWh/day) 95.585 kWh (13.655 kWh/day)
Last 30 Days 620.761 kWh (20.692 kWh/day) 804.732 kWh (26.825 kWh/day) 183.971 kWh (6.132 kWh/day)
Last One Year 6.324 MWh (17.327 kWh/day) 6.396 MWh (17.523 kWh/day) 0.072 MWh (0.196 kWh/day)
Lifetime Since PTO 32.523 MWh (17.454 kW/day) 35.146 MWh (18.862 kW/day) 2.622 MWh (1.407 kW/day)
Lifetime Since Install 32.557 MWh 35.726 MWh 3.168 MWh
Voltage/Current 247.3 V / 3.1 A 247.2 V / 1.1 A 247.3 V / -2.0 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/10/2020 23:21 (12.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.443 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 0.867 1.169 11.496 0.000 kW
0.859 kWh
0.000 kW
5.156 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.256 0.856 1.159 11.384
03 - 202224****** IQ7+M [5] VCOP 0.000 0.256 0.869 1.179 11.594
04 - 202232****** IQ7+ [5] VCOP 0.000 0.257 0.861 1.170 11.572
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 0.848 1.131 11.038
06 - 202245****** IQ7+M [5] VCOP 0.000 0.256 0.855 1.145 11.038
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.251 0.826 1.147 11.472 0.000 kW
0.830 kWh
0.000 kW
4.152 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.248 0.822 1.130 11.179
09 - 202217****** IQ7+ [5] VCOP 0.000 0.253 0.833 1.142 11.385
10 - 202244****** IQ7+M [5] VCOP 0.000 0.257 0.840 1.170 11.690
11 - 202224****** IQ7+M [5] VCOP 0.000 0.253 0.832 1.159 11.658
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.231 0.781 1.034 10.020 0.000 kW
0.784 kWh
0.000 kW
3.135 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.228 0.782 1.030 9.822
14 - 202216****** IQ7+ [5] VCOP 0.000 0.229 0.791 1.049 10.056
15 - 202245****** IQ7+M [5] VCOP 0.000 0.226 0.781 1.035 9.902
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.61 V Current/Power 180.01 A (10.371 kW)
Remain Capacity/Energy 582.6 Ah (29.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.6 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-09-10 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 57.61 V Cell (MIN/MAX) 3.585 V / 3.605 V (0.020 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 194.2 Ah (9.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.6 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-10 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.601 V 3.598 V 3.601 V 3.599 V 3.600 V 3.600 V 3.600 V 3.604 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.585 V 3.600 V 3.598 V 3.603 V 3.603 V 3.603 V 3.604 V 3.605 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -