Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.044 kW
09/14/2025 07:45 (1936 days) Production Consumption NET Usage
Now 0.351 kW 0.307 kW -0.044 kW
Today 0.167 kWh (0.021 kW) 3.203 kWh (0.412 kW) 3.036 kWh (0.390 kW)
  - This Week 0.167 kWh (0.515 kWh/day) 3.203 kWh (9.881 kWh/day) 3.036 kWh (9.366 kWh/day)
  - This Month 285.936 kWh (21.461 kWh/day) 307.760 kWh (23.099 kWh/day) 21.824 kWh (1.638 kWh/day)
  - This Year 4.793 MWh (18.700 kWh/day) 5.479 MWh (21.373 kWh/day) 0.685 MWh (2.673 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.244 MWh (17.685 kW/day) 37.430 MWh (19.331 kW/day) 3.186 MWh (1.646 kW/day)
Lifetime Since Install 34.278 MWh 38.010 MWh 3.732 MWh
Voltage/Current 254.2 V / 1.4 A 254.2 V / 1.2 A 254.2 V / -0.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/22/2020 21:07 (8.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.277 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.042 0.158 0.841 5.800 0.000 kW
0.156 kWh
0.000 kW
0.935 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.041 0.154 0.814 5.685
03 - 202224****** IQ7+M [5] VCOP 0.000 0.042 0.159 0.803 5.675
04 - 202232****** IQ7+ [5] VCOP 0.000 0.041 0.156 0.767 5.479
05 - 202244****** IQ7+M [5] VCOP 0.000 0.040 0.153 0.846 5.819
06 - 202245****** IQ7+M [5] VC-- 0.000 0.041 0.155 0.840 5.759
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.037 0.140 0.912 6.573 0.000 kW
0.141 kWh
0.000 kW
0.703 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.037 0.139 0.801 5.954
09 - 202217****** IQ7+ [5] VCOP 0.000 0.037 0.141 0.973 7.093
10 - 202244****** IQ7+M [5] VCOP 0.000 0.037 0.143 0.969 7.036
11 - 202224****** IQ7+M [5] VCOP 0.000 0.037 0.140 0.904 6.650
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.041 0.158 0.482 3.090 0.000 kW
0.160 kWh
0.000 kW
0.639 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.041 0.160 0.520 3.374
14 - 202216****** IQ7+ [5] VCOP 0.000 0.042 0.162 0.521 3.363
15 - 202245****** IQ7+M [5] VCOP 0.000 0.041 0.159 0.507 3.275
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 51.81 V Current/Power 161.80 A (8.383 kW)
Remain Capacity/Energy 166.8 Ah (8.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 28.2 % State Of Health 98.5 %
Run Time 2h 37m to full Report Date 2020-11-22 23:59
voltag, current for each battery pack voltage, current, and SOC

Voltage 51.81 V Cell (MIN/MAX) 3.231 V / 3.244 V (0.013 V)
Current/Power -0.45 A (-23 W) Runtime 5d 3h 33m to empty
Remain Capacity/Energy 55.6 Ah (2.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 28.2 % State Of Health 98.5 %
Temperature 26.0 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-22 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.231 V 3.233 V 3.235 V 3.235 V 3.237 V 3.236 V 3.239 V 3.239 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.238 V 3.237 V 3.240 V 3.239 V 3.241 V 3.242 V 3.243 V 3.244 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -