Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.176 kW
11/02/2025 19:53 (1985 days) Production Consumption NET Usage
Now 0.000 kW 0.176 kW 0.176 kW
Today 17.171 kWh (0.863 kW) 20.791 kWh (1.045 kW) 3.620 kWh (0.182 kW)
  - This Week 17.171 kWh (20.713 kWh/day) 20.791 kWh (25.080 kWh/day) 3.620 kWh (4.367 kWh/day)
  - This Month 34.109 kWh (18.645 kWh/day) 36.979 kWh (20.214 kWh/day) 2.870 kWh (1.569 kWh/day)
  - This Year 5.612 MWh (18.350 kWh/day) 6.369 MWh (20.827 kWh/day) 0.757 MWh (2.476 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.063 MWh (17.656 kW/day) 38.322 MWh (19.297 kW/day) 3.259 MWh (1.641 kW/day)
Lifetime Since Install 35.097 MWh 38.902 MWh 3.805 MWh
Voltage/Current 247.4 V / 0.0 A 247.3 V / 0.7 A 247.3 V / 0.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/14/2021 21:00 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.154 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.160 0.577 0.466 5.312 0.000 kW
0.558 kWh
0.000 kW
3.346 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.154 0.541 0.432 4.943
03 - 202224****** IQ7+M [0] ---- 0.000 0.159 0.563 0.452 4.969
04 - 202232****** IQ7+ [0] ---- 0.000 0.161 0.571 0.458 4.810
05 - 202244****** IQ7+M [0] ---- 0.000 0.156 0.537 0.426 5.265
06 - 202245****** IQ7+M [0] ---- 0.000 0.156 0.557 0.444 5.384
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.224 0.607 0.494 6.370 0.000 kW
0.612 kWh
0.000 kW
3.061 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.222 0.562 0.487 5.578
09 - 202217****** IQ7+ [0] ---- 0.000 0.224 0.645 0.500 6.869
10 - 202244****** IQ7+M [0] ---- 0.000 0.226 0.645 0.503 6.812
11 - 202224****** IQ7+M [0] ---- 0.000 0.223 0.602 0.494 6.304
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.100 0.435 0.346 2.715 0.000 kW
0.437 kWh
0.000 kW
1.747 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.100 0.437 0.353 2.972
14 - 202216****** IQ7+ [0] ---- 0.000 0.100 0.442 0.357 2.969
15 - 202245****** IQ7+M [0] ---- 0.000 0.098 0.433 0.349 2.886
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.23 V Current/Power -0.30 A (-15 W)
Remain Capacity/Energy 496.5 Ah (25.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 84.0 % State Of Health 98.5 %
Run Time 68d 22h 59m to empty Report Date 2021-01-14 23:56
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.27 A (-14 W) Runtime 25d 19h 51m to empty
Remain Capacity/Energy 165.5 Ah (8.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 84.0 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-14 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.322 V 3.323 V 3.324 V 3.324 V 3.325 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.327 V 3.328 V 3.329 V 3.330 V 3.331 V 3.331 V 3.331 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -