Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.582 kW
02/02/2026 16:19 (2077 days) Production Consumption NET Usage
Now 0.362 kW 1.944 kW 1.582 kW
Today 20.253 kWh (1.240 kW) 7.956 kWh (0.487 kW) -12.297 kWh (-0.753 kW)
  - This Week 42.437 kWh (25.240 kWh/day) 64.842 kWh (38.566 kWh/day) 22.405 kWh (13.326 kWh/day)
  - This Month 42.437 kWh (25.240 kWh/day) 64.842 kWh (38.566 kWh/day) 22.405 kWh (13.326 kWh/day)
  - This Year 0.288 MWh (8.808 kWh/day) 0.648 MWh (19.829 kWh/day) 0.360 MWh (11.021 kWh/day)
Yesterday 22.184 kWh (0.924 kW) 56.886 kWh (2.369 kW) 34.702 kWh (1.445 kW)
Last 7 Days 81.933 kWh (12.965 kWh/day) 136.275 kWh (21.565 kWh/day) 54.342 kWh (8.599 kWh/day)
Last 30 Days 242.590 kWh (8.274 kWh/day) 604.131 kWh (20.605 kWh/day) 361.541 kWh (12.331 kWh/day)
Last One Year 6.090 MWh (16.716 kWh/day) 7.539 MWh (20.694 kWh/day) 1.449 MWh (3.978 kWh/day)
Lifetime Since PTO 35.854 MWh (17.256 kW/day) 40.159 MWh (19.329 kW/day) 4.306 MWh (2.072 kW/day)
Lifetime Since Install 35.887 MWh 40.739 MWh 4.852 MWh
Voltage/Current 249.9 V / 1.4 A 249.9 V / 7.8 A 249.9 V / 6.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/22/2021 22:46 (13.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.399 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 1.574 1.197 7.907 0.000 kW
1.536 kWh
0.000 kW
9.213 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.300 1.527 1.158 7.631
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.572 1.193 7.906
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.596 1.214 8.013
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.435 1.089 7.134
06 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.510 1.141 7.450
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.470 1.114 7.216 0.000 kW
1.476 kWh
0.000 kW
7.381 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.436 1.085 7.055
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.486 1.122 7.283
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 1.501 1.140 7.427
11 - 202224****** IQ7+M [5] VCOP 0.000 0.302 1.488 1.131 7.382
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.296 1.718 1.216 8.247 0.000 kW
1.701 kWh
0.000 kW
6.805 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.295 1.685 1.198 8.116
14 - 202216****** IQ7+ [0] V--- 0.000 0.293 1.713 1.226 8.269
15 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.689 1.213 8.153
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.