Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.842 kW
09/14/2025 09:02 (1936 days) Production Consumption NET Usage
Now 1.103 kW 0.261 kW -0.842 kW
Today 0.977 kWh (0.108 kW) 3.842 kWh (0.424 kW) 2.865 kWh (0.316 kW)
  - This Week 0.977 kWh (2.586 kWh/day) 3.842 kWh (10.169 kWh/day) 2.865 kWh (7.583 kWh/day)
  - This Month 286.746 kWh (21.436 kWh/day) 308.399 kWh (23.054 kWh/day) 21.653 kWh (1.619 kWh/day)
  - This Year 4.794 MWh (18.699 kWh/day) 5.479 MWh (21.371 kWh/day) 0.685 MWh (2.672 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.245 MWh (17.685 kW/day) 37.431 MWh (19.330 kW/day) 3.186 MWh (1.645 kW/day)
Lifetime Since Install 34.279 MWh 38.011 MWh 3.732 MWh
Voltage/Current 253.9 V / 4.3 A 253.9 V / 1.0 A 253.9 V / -3.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/09/2020 21:58 (8.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.433 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.123 0.318 0.369 3.936 0.000 kW
0.316 kWh
0.000 kW
1.898 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.138 0.309 0.364 3.820
03 - 202224****** IQ7+M [5] VCOP 0.000 0.141 0.320 0.377 3.783
04 - 202232****** IQ7+ [5] VCOP 0.000 0.112 0.303 0.373 3.611
05 - 202244****** IQ7+M [5] VCOP 0.000 0.159 0.323 0.376 4.092
06 - 202245****** IQ7+M [5] VCOP 0.000 0.169 0.325 0.364 4.067
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.198 0.331 0.434 4.878 0.000 kW
0.280 kWh
0.000 kW
1.401 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.056 0.051 0.433 4.439
09 - 202217****** IQ7+ [5] VCOP 0.000 0.204 0.347 0.462 5.206
10 - 202244****** IQ7+M [5] VCOP 0.000 0.200 0.340 0.462 5.179
11 - 202224****** IQ7+M [5] VCOP 0.000 0.200 0.332 0.454 4.872
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.101 0.278 0.256 2.012 0.000 kW
0.283 kWh
0.000 kW
1.134 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.104 0.286 0.259 2.202
14 - 202216****** IQ7+ [5] VCOP 0.000 0.102 0.291 0.262 2.198
15 - 202245****** IQ7+M [5] VCOP 0.000 0.101 0.279 0.257 2.146
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.49 V Current/Power 163.92 A (8.605 kW)
Remain Capacity/Energy 334.2 Ah (17.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 56.5 % State Of Health 98.5 %
Run Time 1h 33m to full Report Date 2020-12-09 21:48
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.49 V Cell (MIN/MAX) 3.276 V / 3.285 V (0.009 V)
Current/Power -0.55 A (-28 W) Runtime 8d 10h 32m to empty
Remain Capacity/Energy 111.4 Ah (5.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 56.5 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-09 21:48
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.276 V 3.276 V 3.277 V 3.278 V 3.279 V 3.278 V 3.280 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.283 V 3.282 V 3.283 V 3.284 V 3.285 V 3.285 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -