Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.147 kW
06/29/2026 11:28 (2224 days) Production Consumption NET Usage
Now 3.488 kW 2.341 kW -1.147 kW
Today 8.526 kWh (0.743 kW) 6.936 kWh (0.604 kW) -1.590 kWh (-0.139 kW)
  - This Week 35.587 kWh (24.073 kWh/day) 35.245 kWh (23.842 kWh/day) -0.342 kWh (-0.231 kWh/day)
  - This Month 829.414 kWh (29.123 kWh/day) 677.941 kWh (23.805 kWh/day) -151.473 kWh (-5.319 kWh/day)
  - This Year 3.564 MWh (19.857 kWh/day) 3.248 MWh (18.096 kWh/day) -0.316 MWh (-1.760 kWh/day)
Yesterday 27.061 kWh (1.128 kW) 28.309 kWh (1.180 kW) 1.248 kWh (0.052 kW)
Last 7 Days 139.566 kWh (19.938 kWh/day) 172.293 kWh (24.613 kWh/day) 32.727 kWh (4.675 kWh/day)
Last 30 Days (05/30/2026) 879.669 kWh (29.322 kWh/day) 685.708 kWh (22.857 kWh/day) -193.961 kWh (-6.465 kWh/day)
Last One Year 6.698 MWh (18.351 kWh/day) 7.737 MWh (21.198 kWh/day) 1.039 MWh (2.848 kWh/day)
Lifetime Since PTO 39.130 MWh (17.590 kW/day) 42.759 MWh (19.222 kW/day) 3.629 MWh (1.631 kW/day)
Lifetime Since Install 39.163 MWh 43.339 MWh 4.175 MWh
Voltage/Current 249.5 V / 14.0 A 249.3 V / 9.4 A 249.4 V / -4.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/24/2021 23:02 (11.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.852 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.273 1.857 0.686 8.164 0.000 kW
1.814 kWh
0.000 kW
10.884 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.266 1.815 0.666 7.898
03 - 202224****** IQ7+M [5] VCOP 0.000 0.273 1.833 0.692 8.217
04 - 202232****** IQ7+ [5] VCOP 0.000 0.271 1.824 0.686 8.112
05 - 202244****** IQ7+M [5] VCOP 0.000 0.270 1.788 0.662 7.832
06 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.767 0.666 7.755
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.970 0.651 8.244 0.000 kW
1.950 kWh
0.000 kW
9.749 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.839 0.650 7.729
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.974 0.664 8.281
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 1.978 0.663 8.295
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.988 0.660 8.300
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.203 1.321 0.628 6.805 0.000 kW
1.305 kWh
0.000 kW
5.219 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.201 1.275 0.634 6.701
14 - 202216****** IQ7+ [5] VCOP 0.000 0.202 1.326 0.642 6.894
15 - 202245****** IQ7+M [5] VCOP 0.000 0.200 1.298 0.629 6.773
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [4] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 512.4 Ah (26.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.4 % State Of Health 100.0 %
Run Time 14d 5h 36m to empty Report Date 2021-09-24 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.