Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.420 kW
02/02/2026 16:21 (2077 days) Production Consumption NET Usage
Now 0.392 kW 1.812 kW 1.420 kW
Today 20.264 kWh (1.239 kW) 8.006 kWh (0.489 kW) -12.258 kWh (-0.749 kW)
  - This Week 42.448 kWh (25.231 kWh/day) 64.892 kWh (38.571 kWh/day) 22.444 kWh (13.340 kWh/day)
  - This Month 42.448 kWh (25.231 kWh/day) 64.892 kWh (38.571 kWh/day) 22.444 kWh (13.340 kWh/day)
  - This Year 0.288 MWh (8.808 kWh/day) 0.648 MWh (19.830 kWh/day) 0.360 MWh (11.022 kWh/day)
Yesterday 22.184 kWh (0.924 kW) 56.886 kWh (2.369 kW) 34.702 kWh (1.445 kW)
Last 7 Days 81.944 kWh (12.970 kWh/day) 136.309 kWh (21.575 kWh/day) 54.365 kWh (8.605 kWh/day)
Last 30 Days 242.589 kWh (8.274 kWh/day) 604.114 kWh (20.606 kWh/day) 361.525 kWh (12.331 kWh/day)
Last One Year 6.090 MWh (16.716 kWh/day) 7.539 MWh (20.694 kWh/day) 1.449 MWh (3.978 kWh/day)
Lifetime Since PTO 35.854 MWh (17.256 kW/day) 40.160 MWh (19.329 kW/day) 4.306 MWh (2.072 kW/day)
Lifetime Since Install 35.887 MWh 40.740 MWh 4.852 MWh
Voltage/Current 250.4 V / 1.6 A 250.3 V / 7.2 A 250.3 V / 5.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/08/2021 23:05 (13.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.093 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.281 0.632 1.770 10.440 0.000 kW
0.619 kWh
0.000 kW
3.711 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.610 1.686 10.078
03 - 202224****** IQ7+M [5] VCOP 0.000 0.277 0.633 1.728 10.295
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 0.628 1.767 10.386
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.596 1.541 9.580
06 - 202245****** IQ7+M [5] VCOP 0.000 0.286 0.612 1.682 10.022
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.284 0.572 1.578 9.726 0.000 kW
0.574 kWh
0.000 kW
2.870 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.280 0.567 1.539 9.749
09 - 202217****** IQ7+ [5] VCOP 0.000 0.276 0.576 1.576 9.788
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 0.583 1.588 9.959
11 - 202224****** IQ7+M [5] VCOP 0.000 0.270 0.572 1.575 9.925
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.266 0.624 1.980 10.241 0.000 kW
0.628 kWh
0.000 kW
2.513 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.261 0.626 1.972 9.949
14 - 202216****** IQ7+ [0] V--- 0.000 0.264 0.637 1.997 10.283
15 - 202245****** IQ7+M [0] ---- 0.000 0.265 0.626 1.977 10.132
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.18 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 504.0 Ah (25.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.0 % State Of Health 100.0 %
Run Time 23d 8h 0m to empty Report Date 2021-05-08 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.