Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.398 kW
09/14/2025 06:00 (1936 days) Production Consumption NET Usage
Now 0.000 kW 0.398 kW 0.398 kW
Today 0.000 kWh (0.000 kW) 2.320 kWh (0.385 kW) 2.320 kWh (0.385 kW)
  - This Week 0.000 kWh (0.000 kWh/day) 2.320 kWh (9.247 kWh/day) 2.320 kWh (9.247 kWh/day)
  - This Month 285.769 kWh (21.567 kWh/day) 306.877 kWh (23.160 kWh/day) 21.108 kWh (1.593 kWh/day)
  - This Year 4.793 MWh (18.705 kWh/day) 5.478 MWh (21.376 kWh/day) 0.685 MWh (2.671 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.244 MWh (17.686 kW/day) 37.430 MWh (19.331 kW/day) 3.186 MWh (1.645 kW/day)
Lifetime Since Install 34.278 MWh 38.010 MWh 3.732 MWh
Voltage/Current 254.3 V / 0.0 A 254.3 V / 1.6 A 254.3 V / 1.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/22/2020 21:38 (8.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.845 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.089 0.098 0.008 1.118 0.000 kW
0.326 kWh
0.000 kW
1.953 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.172 0.166 0.009 1.075
03 - 202224****** IQ7+M [0] ---- 0.000 0.198 0.260 0.022 1.072
04 - 202232****** IQ7+ [0] ---- 0.000 0.198 0.332 0.024 1.018
05 - 202244****** IQ7+M [0] ---- 0.000 0.192 0.526 0.298 1.399
06 - 202245****** IQ7+M [0] ---- 0.000 0.192 0.571 0.369 1.509
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.273 0.703 0.517 1.845 0.000 kW
0.699 kWh
0.000 kW
3.493 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.275 0.658 0.100 0.149
09 - 202217****** IQ7+ [0] ---- 0.000 0.272 0.718 0.816 2.279
10 - 202244****** IQ7+M [0] ---- 0.000 0.275 0.718 0.823 2.370
11 - 202224****** IQ7+M [0] ---- 0.000 0.271 0.696 0.301 1.648
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.097 0.324 0.237 1.271 0.000 kW
0.350 kWh
0.000 kW
1.399 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.108 0.360 0.276 1.142
14 - 202216****** IQ7+ [0] ---- 0.000 0.105 0.362 0.275 1.113
15 - 202245****** IQ7+M [0] ---- 0.000 0.102 0.352 0.268 1.931
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 51.98 V Current/Power 162.28 A (8.435 kW)
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Run Time 2h 26m to full Report Date 2020-12-22 16:35
voltag, current for each battery pack voltage, current, and SOC

Voltage 51.98 V Cell (MIN/MAX) 3.241 V / 3.254 V (0.013 V)
Current/Power -0.50 A (-26 W) Runtime 5d 8h 30m to empty
Remain Capacity/Energy 64.5 Ah (3.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-22 16:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.241 V 3.242 V 3.244 V 3.244 V 3.249 V 3.245 V 3.249 V 3.249 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.248 V 3.251 V 3.249 V 3.252 V 3.253 V 3.254 V 3.254 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -