Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.613 kW
07/02/2025 06:41 (1862 days) Production Consumption NET Usage
Now 0.117 kW 0.730 kW 0.613 kW
Today 0.019 kWh (0.003 kW) 5.468 kWh (0.814 kW) 5.449 kWh (0.811 kW)
  - This Week 78.287 kWh (23.877 kWh/day) 104.513 kWh (31.876 kWh/day) 26.226 kWh (7.999 kWh/day)
  - This Month 21.001 kWh (16.414 kWh/day) 36.831 kWh (28.786 kWh/day) 15.830 kWh (12.372 kWh/day)
  - This Year 3.051 MWh (16.736 kWh/day) 3.164 MWh (17.358 kWh/day) 0.113 MWh (0.622 kWh/day)
Yesterday 20.982 kWh (0.875 kW) 31.363 kWh (1.307 kW) 10.381 kWh (0.433 kW)
Last 7 Days 152.396 kWh (21.775 kWh/day) 245.602 kWh (35.092 kWh/day) 93.206 kWh (13.317 kWh/day)
Last 30 Days 630.263 kWh (21.010 kWh/day) 789.503 kWh (26.318 kWh/day) 159.240 kWh (5.308 kWh/day)
Last One Year 6.340 MWh (17.370 kWh/day) 6.420 MWh (17.588 kWh/day) 0.079 MWh (0.218 kWh/day)
Lifetime Since PTO 32.502 MWh (17.453 kW/day) 35.116 MWh (18.856 kW/day) 2.614 MWh (1.404 kW/day)
Lifetime Since Install 32.536 MWh 35.696 MWh 3.161 MWh
Voltage/Current 249.5 V / 0.5 A 249.6 V / 2.9 A 249.5 V / 2.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/18/2020 22:19 (10.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.464 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.276 1.247 1.650 6.004 0.000 kW
1.242 kWh
0.000 kW
7.454 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.233 1.609 5.878
03 - 202224****** IQ7+M [5] VCOP 0.000 0.279 1.252 1.624 5.939
04 - 202232****** IQ7+ [5] VCOP 0.000 0.279 1.245 1.608 5.865
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.243 1.626 5.895
06 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.235 1.629 5.910
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.286 1.844 6.430 0.000 kW
1.298 kWh
0.000 kW
6.492 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.166 1.704 6.030
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.353 1.906 6.602
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.357 1.928 6.698
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.330 1.897 6.594
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.189 0.865 0.957 4.013 0.000 kW
0.879 kWh
0.000 kW
3.517 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.189 0.883 0.991 4.057
14 - 202216****** IQ7+ [5] VCOP 0.000 0.190 0.892 1.002 4.153
15 - 202245****** IQ7+M [5] VCOP 0.000 0.188 0.878 0.982 4.079
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.69 V Current/Power 164.32 A (8.658 kW)
Remain Capacity/Energy 372.9 Ah (19.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 63.1 % State Of Health 98.5 %
Run Time 1h 19m to full Report Date 2020-10-18 18:38
voltag, current for each battery pack voltage, current, and SOC

Voltage 52.69 V Cell (MIN/MAX) 3.284 V / 3.305 V (0.021 V)
Current/Power -0.48 A (-25 W) Runtime 10d 18h 59m to empty
Remain Capacity/Energy 124.3 Ah (6.4 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 63.1 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-18 18:38
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.285 V 3.284 V 3.285 V 3.285 V 3.290 V 3.286 V 3.289 V 3.288 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.296 V 3.289 V 3.301 V 3.291 V 3.302 V 3.303 V 3.304 V 3.305 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -