Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.144 kW
09/14/2025 08:24 (1936 days) Production Consumption NET Usage
Now 0.560 kW 0.416 kW -0.144 kW
Today 0.464 kWh (0.055 kW) 3.368 kWh (0.399 kW) 2.904 kWh (0.344 kW)
  - This Week 0.464 kWh (1.321 kWh/day) 3.368 kWh (9.585 kWh/day) 2.904 kWh (8.265 kWh/day)
  - This Month 286.233 kWh (21.440 kWh/day) 307.925 kWh (23.065 kWh/day) 21.692 kWh (1.625 kWh/day)
  - This Year 4.794 MWh (18.699 kWh/day) 5.479 MWh (21.372 kWh/day) 0.685 MWh (2.672 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.244 MWh (17.685 kW/day) 37.431 MWh (19.331 kW/day) 3.186 MWh (1.645 kW/day)
Lifetime Since Install 34.278 MWh 38.011 MWh 3.732 MWh
Voltage/Current 252.5 V / 2.2 A 252.4 V / 1.6 A 252.4 V / -0.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/03/2021 21:23 (8.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.697 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.021 0.050 0.700 4.143 0.000 kW
0.047 kWh
0.000 kW
0.285 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.020 0.042 0.669 3.830
03 - 202224****** IQ7+M [5] VCOP 0.000 0.019 0.046 0.682 3.870
04 - 202232****** IQ7+ [5] VCOP 0.000 0.019 0.047 0.661 3.790
05 - 202244****** IQ7+M [5] VCOP 0.000 0.021 0.046 0.698 4.045
06 - 202245****** IQ7+M [5] VCOP 0.000 0.023 0.053 0.713 4.220
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.018 0.047 0.881 5.166 0.000 kW
0.042 kWh
0.000 kW
0.211 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.017 0.042 0.791 4.638
09 - 202217****** IQ7+ [5] VCOP 0.000 0.016 0.041 0.964 5.495
10 - 202244****** IQ7+M [5] VCOP 0.000 0.017 0.041 0.956 5.466
11 - 202224****** IQ7+M [5] VCOP 0.000 0.017 0.040 0.896 5.130
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.021 0.053 0.310 2.080 0.000 kW
0.050 kWh
0.000 kW
0.202 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.021 0.050 0.338 2.291
14 - 202216****** IQ7+ [5] VCOP 0.000 0.020 0.050 0.339 2.292
15 - 202245****** IQ7+M [5] VCOP 0.000 0.020 0.049 0.330 2.237
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.19 V Current/Power 166.13 A (8.837 kW)
Remain Capacity/Energy 452.7 Ah (23.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 76.6 % State Of Health 98.5 %
Run Time 49m to full Report Date 2021-01-03 23:42
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.19 V Cell (MIN/MAX) 3.318 V / 3.329 V (0.011 V)
Current/Power -0.26 A (-13 W) Runtime 23d 21h 45m to empty
Remain Capacity/Energy 150.9 Ah (7.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 76.6 % State Of Health 98.5 %
Temperature 18.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-03 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.320 V 3.320 V 3.321 V 3.322 V 3.323 V 3.323 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V 3.328 V 3.329 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -