Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.030 kW
02/02/2026 12:31 (2077 days) Production Consumption NET Usage
Now 3.118 kW 0.088 kW -3.030 kW
Today 11.439 kWh (0.913 kW) 6.250 kWh (0.499 kW) -5.189 kWh (-0.414 kW)
  - This Week 33.623 kWh (22.076 kWh/day) 63.136 kWh (41.454 kWh/day) 29.513 kWh (19.378 kWh/day)
  - This Month 33.623 kWh (22.076 kWh/day) 63.136 kWh (41.454 kWh/day) 29.513 kWh (19.378 kWh/day)
  - This Year 0.279 MWh (8.580 kWh/day) 0.646 MWh (19.873 kWh/day) 0.367 MWh (11.293 kWh/day)
Yesterday 22.184 kWh (0.924 kW) 56.886 kWh (2.369 kW) 34.702 kWh (1.445 kW)
Last 7 Days 73.148 kWh (11.292 kWh/day) 137.206 kWh (21.180 kWh/day) 64.058 kWh (9.889 kWh/day)
Last 30 Days 246.500 kWh (8.362 kWh/day) 607.911 kWh (20.623 kWh/day) 361.411 kWh (12.261 kWh/day)
Last One Year 6.093 MWh (16.717 kWh/day) 7.541 MWh (20.689 kWh/day) 1.448 MWh (3.972 kWh/day)
Lifetime Since PTO 35.845 MWh (17.253 kW/day) 40.158 MWh (19.329 kW/day) 4.313 MWh (2.076 kW/day)
Lifetime Since Install 35.879 MWh 40.738 MWh 4.859 MWh
Voltage/Current 251.2 V / 12.4 A 251.2 V / 0.4 A 251.2 V / -12.1 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/02/2021 23:35 (13.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.757 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.029 0.969 12.366 0.000 kW
1.013 kWh
0.000 kW
6.080 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 0.998 0.925 11.880
03 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.039 0.918 11.998
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.025 0.935 12.098
05 - 202244****** IQ7+M [5] VCOP 0.000 0.289 0.993 0.767 11.008
06 - 202245****** IQ7+M [5] VCOP 0.000 0.288 0.996 0.938 11.998
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.275 0.935 0.796 10.879 0.000 kW
0.945 kWh
0.000 kW
4.727 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.268 0.945 0.784 11.184
09 - 202217****** IQ7+ [5] VCOP 0.000 0.268 0.943 0.798 11.111
10 - 202244****** IQ7+M [5] VCOP 0.000 0.270 0.956 0.805 11.338
11 - 202224****** IQ7+M [5] VCOP 0.000 0.271 0.948 0.795 11.338
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.273 0.986 1.094 12.151 0.000 kW
0.987 kWh
0.000 kW
3.949 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.269 0.975 1.086 11.767
14 - 202216****** IQ7+ [5] VCOP 0.000 0.277 1.003 1.102 12.175
15 - 202245****** IQ7+M [5] VCOP 0.000 0.273 0.985 1.087 11.987
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.