Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.805 kW
12/17/2025 07:36 (2030 days) Production Consumption NET Usage
Now 0.117 kW 4.922 kW 4.805 kW
Today 0.013 kWh (0.002 kW) 3.672 kWh (0.482 kW) 3.659 kWh (0.481 kW)
  - This Week 19.016 kWh (5.731 kWh/day) 53.334 kWh (16.072 kWh/day) 34.318 kWh (10.342 kWh/day)
  - This Month 139.767 kWh (8.565 kWh/day) 314.607 kWh (19.280 kWh/day) 174.840 kWh (10.715 kWh/day)
  - This Year 6.009 MWh (17.152 kWh/day) 7.231 MWh (20.641 kWh/day) 1.222 MWh (3.489 kWh/day)
Yesterday 12.430 kWh (0.518 kW) 16.043 kWh (0.668 kW) 3.613 kWh (0.151 kW)
Last 7 Days 56.274 kWh (8.039 kWh/day) 143.442 kWh (20.492 kWh/day) 87.168 kWh (12.452 kWh/day)
Last 30 Days 261.914 kWh (8.730 kWh/day) 564.027 kWh (18.801 kWh/day) 302.113 kWh (10.070 kWh/day)
Last One Year 6.111 MWh (16.742 kWh/day) 7.577 MWh (20.760 kWh/day) 1.466 MWh (4.018 kWh/day)
Lifetime Since PTO 35.460 MWh (17.465 kW/day) 39.184 MWh (19.299 kW/day) 3.724 MWh (1.834 kW/day)
Lifetime Since Install 35.494 MWh 39.764 MWh 4.270 MWh
Voltage/Current 247.5 V / 0.5 A 247.5 V / 19.9 A 247.5 V / 19.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/20/2021 23:13 (14.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.204 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.193 2.172 13.423 0.000 kW
2.122 kWh
0.000 kW
12.733 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 2.116 2.084 12.845
03 - 202224****** IQ7+M [5] VCOP 0.000 0.292 2.139 2.102 12.975
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.176 2.137 13.207
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.981 1.918 11.701
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 2.128 2.092 12.911
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.293 1.984 1.969 11.922 0.000 kW
2.049 kWh
0.000 kW
10.247 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.290 2.053 2.003 12.078
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 2.023 1.985 12.071
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 2.085 2.020 12.254
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 2.101 2.021 12.255
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.265 2.081 2.154 13.930 0.000 kW
2.056 kWh
0.000 kW
8.224 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.267 1.983 2.072 13.534
14 - 202216****** IQ7+ [5] VCOP 0.000 0.267 2.091 2.154 13.926
15 - 202245****** IQ7+M [5] VCOP 0.000 0.264 2.069 2.125 13.748
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.