Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.114 kW
07/02/2025 08:30 (1862 days) Production Consumption NET Usage
Now 0.912 kW 0.798 kW -0.114 kW
Today 0.945 kWh (0.111 kW) 7.411 kWh (0.868 kW) 6.466 kWh (0.757 kW)
  - This Week 79.213 kWh (23.614 kWh/day) 106.456 kWh (31.735 kWh/day) 27.243 kWh (8.121 kWh/day)
  - This Month 21.927 kWh (16.179 kWh/day) 38.774 kWh (28.609 kWh/day) 16.847 kWh (12.430 kWh/day)
  - This Year 3.052 MWh (16.735 kWh/day) 3.166 MWh (17.362 kWh/day) 0.114 MWh (0.627 kWh/day)
Yesterday 20.982 kWh (0.875 kW) 31.363 kWh (1.307 kW) 10.381 kWh (0.433 kW)
Last 7 Days 152.396 kWh (21.775 kWh/day) 245.602 kWh (35.092 kWh/day) 93.206 kWh (13.317 kWh/day)
Last 30 Days 630.263 kWh (21.010 kWh/day) 789.503 kWh (26.318 kWh/day) 159.240 kWh (5.308 kWh/day)
Last One Year 6.340 MWh (17.370 kWh/day) 6.420 MWh (17.588 kWh/day) 0.079 MWh (0.218 kWh/day)
Lifetime Since PTO 32.503 MWh (17.452 kW/day) 35.118 MWh (18.857 kW/day) 2.615 MWh (1.404 kW/day)
Lifetime Since Install 32.536 MWh 35.698 MWh 3.162 MWh
Voltage/Current 248.8 V / 3.7 A 248.7 V / 3.2 A 248.7 V / -0.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/05/2020 21:42 (8.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.176 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.185 0.279 0.207 3.504 0.000 kW
0.285 kWh
0.000 kW
1.712 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.186 0.282 0.203 3.394
03 - 202224****** IQ7+M [5] VCOP 0.000 0.184 0.293 0.208 3.355
04 - 202232****** IQ7+ [5] VCOP 0.000 0.184 0.290 0.205 3.189
05 - 202244****** IQ7+M [5] VCOP 0.000 0.186 0.290 0.202 3.657
06 - 202245****** IQ7+M [5] VCOP 0.000 0.187 0.279 0.204 3.651
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.260 0.326 0.190 4.142 0.000 kW
0.338 kWh
0.000 kW
1.692 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.259 0.334 0.188 3.579
09 - 202217****** IQ7+ [5] VCOP 0.000 0.261 0.343 0.191 4.440
10 - 202244****** IQ7+M [5] VCOP 0.000 0.260 0.344 0.194 4.427
11 - 202224****** IQ7+M [5] VCOP 0.000 0.257 0.345 0.191 4.079
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.079 0.190 0.202 1.977 0.000 kW
0.193 kWh
0.000 kW
0.772 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.083 0.194 0.204 2.134
14 - 202216****** IQ7+ [5] VCOP 0.000 0.081 0.196 0.207 2.131
15 - 202245****** IQ7+M [5] VCOP 0.000 0.080 0.192 0.203 2.078
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.17 V Current/Power 166.07 A (8.830 kW)
Remain Capacity/Energy 466.8 Ah (23.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 79.0 % State Of Health 98.5 %
Run Time 44m to full Report Date 2020-12-05 23:27
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.17 V Cell (MIN/MAX) 3.317 V / 3.328 V (0.011 V)
Current/Power -0.55 A (-29 W) Runtime 11d 18h 54m to empty
Remain Capacity/Energy 155.6 Ah (8.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 79.0 % State Of Health 98.5 %
Temperature 21.5 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-12-05 23:27
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.319 V 3.319 V 3.320 V 3.321 V 3.321 V 3.322 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.324 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -