Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.196 kW
07/02/2025 08:08 (1862 days) Production Consumption NET Usage
Now 0.650 kW 0.454 kW -0.196 kW
Today 0.630 kWh (0.077 kW) 6.981 kWh (0.854 kW) 6.351 kWh (0.777 kW)
  - This Week 78.898 kWh (23.626 kWh/day) 106.026 kWh (31.749 kWh/day) 27.128 kWh (8.123 kWh/day)
  - This Month 21.612 kWh (16.126 kWh/day) 38.344 kWh (28.610 kWh/day) 16.732 kWh (12.485 kWh/day)
  - This Year 3.051 MWh (16.734 kWh/day) 3.166 MWh (17.361 kWh/day) 0.114 MWh (0.627 kWh/day)
Yesterday 20.982 kWh (0.875 kW) 31.363 kWh (1.307 kW) 10.381 kWh (0.433 kW)
Last 7 Days 152.396 kWh (21.775 kWh/day) 245.602 kWh (35.092 kWh/day) 93.206 kWh (13.317 kWh/day)
Last 30 Days 630.263 kWh (21.010 kWh/day) 789.503 kWh (26.318 kWh/day) 159.240 kWh (5.308 kWh/day)
Last One Year 6.340 MWh (17.370 kWh/day) 6.420 MWh (17.588 kWh/day) 0.079 MWh (0.218 kWh/day)
Lifetime Since PTO 32.502 MWh (17.452 kW/day) 35.118 MWh (18.857 kW/day) 2.615 MWh (1.404 kW/day)
Lifetime Since Install 32.536 MWh 35.698 MWh 3.161 MWh
Voltage/Current 247.8 V / 2.6 A 247.8 V / 1.8 A 247.8 V / -0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/11/2020 21:40 (8.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.585 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.185 0.738 0.764 3.718 0.000 kW
0.721 kWh
0.000 kW
4.328 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.183 0.709 0.742 3.615
03 - 202224****** IQ7+M [5] VCOP 0.000 0.186 0.692 0.726 3.595
04 - 202232****** IQ7+ [5] VCOP 0.000 0.182 0.657 0.681 3.425
05 - 202244****** IQ7+M [5] VCOP 0.000 0.186 0.756 0.809 3.862
06 - 202245****** IQ7+M [5] VCOP 0.000 0.184 0.777 0.821 3.849
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.237 0.914 0.999 4.613 0.000 kW
0.751 kWh
0.000 kW
3.755 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.000 3.119
09 - 202217****** IQ7+ [5] VCOP 0.000 0.240 0.981 1.097 4.937
10 - 202244****** IQ7+M [5] VCOP 0.000 0.240 0.971 1.077 4.895
11 - 202224****** IQ7+M [5] VCOP 0.000 0.238 0.888 0.980 4.637
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.092 0.348 0.313 1.934 0.000 kW
0.375 kWh
0.000 kW
1.502 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.093 0.390 0.360 2.116
14 - 202216****** IQ7+ [5] VCOP 0.000 0.093 0.389 0.358 2.118
15 - 202245****** IQ7+M [5] VCOP 0.000 0.090 0.375 0.347 2.062
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.29 V Current/Power 166.38 A (8.866 kW)
Remain Capacity/Energy 584.4 Ah (29.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.9 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-12-11 23:26
voltag, current for each battery pack voltage, current, and SOC

Voltage 53.29 V Cell (MIN/MAX) 3.324 V / 3.335 V (0.011 V)
Current/Power -0.50 A (-26 W) Runtime 16d 2h 31m to empty
Remain Capacity/Energy 194.8 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.9 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-11 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.324 V 3.328 V 3.325 V 3.329 V 3.328 V 3.328 V 3.331 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.330 V 3.332 V 3.330 V 3.333 V 3.333 V 3.334 V 3.335 V
pack voltage and current cell voltages
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -