Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.971 kW
01/17/2025 20:03 (1696 days) Production Consumption NET Usage
Now 0.000 kW 1.971 kW 1.971 kW
Today 12.959 kWh (0.646 kW) 12.604 kWh (0.628 kW) -0.355 kWh (-0.018 kW)
  - This Week 68.359 kWh (11.713 kWh/day) 182.311 kWh (31.238 kWh/day) 113.952 kWh (19.525 kWh/day)
  - This Month 173.096 kWh (10.281 kWh/day) 443.301 kWh (26.330 kWh/day) 270.205 kWh (16.049 kWh/day)
  - This Year 0.173 MWh (10.281 kWh/day) 0.443 MWh (26.330 kWh/day) 0.270 MWh (16.049 kWh/day)
Yesterday 7.632 kWh (0.318 kW) 55.288 kWh (2.304 kW) 47.656 kWh (1.986 kW)
Last 7 Days 72.337 kWh (10.334 kWh/day) 212.974 kWh (30.424 kWh/day) 140.637 kWh (20.091 kWh/day)
Last 30 Days 251.946 kWh (8.398 kWh/day) 768.107 kWh (25.604 kWh/day) 516.161 kWh (17.206 kWh/day)
Last One Year 6.757 MWh (18.512 kWh/day) 6.391 MWh (17.509 kWh/day) -0.366 MWh (-1.003 kWh/day)
Lifetime Since PTO 29.624 MWh (17.458 kW/day) 32.396 MWh (19.092 kW/day) 2.772 MWh (1.634 kW/day)
Lifetime Since Install 29.658 MWh 32.976 MWh 3.318 MWh
Voltage/Current 247.7 V / 0.0 A 247.8 V / 8.0 A 247.8 V / 8.0 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 08/12/2020 23:03 (13.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.250 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.297 1.547 1.764 11.247 0.000 kW
1.498 kWh
0.000 kW
8.987 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.296 1.497 1.737 10.991
03 - 202224101754 IQ7+M ---- 0.000 0.297 1.530 1.769 11.185
04 - 202232127100 IQ7+ ---- 0.000 0.297 1.543 1.767 11.206
05 - 202244171601 IQ7+M ---- 0.000 0.295 1.388 1.639 10.434
06 - 202245013024 IQ7+M ---- 0.000 0.294 1.482 1.732 10.943
front 07 - 202206091803 IQ7+ ---- 0.000 0.297 1.363 1.673 10.478 0.000 kW
1.389 kWh
0.000 kW
6.947 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.298 1.383 1.720 10.633
09 - 202217001404 IQ7+ ---- 0.000 0.295 1.369 1.684 10.545
10 - 202244165234 IQ7+M ---- 0.000 0.296 1.417 1.742 10.772
11 - 202224104308 IQ7+M ---- 0.000 0.296 1.416 1.745 10.770
back 12 - 202211186551 IQ7+ ---- 0.000 0.261 1.586 1.577 10.431 0.000 kW
1.579 kWh
0.000 kW
6.316 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.262 1.574 1.505 10.120
14 - 202216155993 IQ7+ ---- 0.000 0.264 1.590 1.588 10.489
15 - 202245015670 IQ7+M ---- 0.000 0.258 1.565 1.566 10.334
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 57.61 V Current/Power 179.98 A (10.368 kW)
Remain Capacity/Energy 568.8 Ah (29.1 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.5 % State Of Health 96.2 %
Run Time 2m to full Report Date 2020-08-12 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.61 V Cell (MIN/MAX) 3.581 V / 3.604 V (0.023 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 189.6 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.5 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-12 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.599 V 3.598 V 3.600 V 3.593 V 3.581 V 3.602 V 3.604 V 3.603 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.602 V 3.602 V 3.603 V 3.603 V 3.603 V 3.603 V 3.603 V 3.604 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -