Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.463 kW
10/31/2025 20:27 (1983 days) Production Consumption NET Usage
Now 0.000 kW 0.463 kW 0.463 kW
Today 11.508 kWh (0.562 kW) 8.963 kWh (0.438 kW) -2.545 kWh (-0.124 kW)
  - This Week 67.616 kWh (11.553 kWh/day) 47.084 kWh (8.045 kWh/day) -20.532 kWh (-3.508 kWh/day)
  - This Month 478.702 kWh (15.516 kWh/day) 472.024 kWh (15.299 kWh/day) -6.678 kWh (-0.216 kWh/day)
  - This Year 5.578 MWh (18.357 kWh/day) 6.327 MWh (20.823 kWh/day) 0.749 MWh (2.465 kWh/day)
Yesterday 1.140 kWh (0.047 kW) 14.195 kWh (0.591 kW) 13.055 kWh (0.544 kW)
Last 7 Days 83.693 kWh (11.956 kWh/day) 45.007 kWh (6.429 kWh/day) -38.686 kWh (-5.526 kWh/day)
Last 30 Days 467.194 kWh (15.573 kWh/day) 463.061 kWh (15.435 kWh/day) -4.133 kWh (-0.138 kWh/day)
Last One Year 6.212 MWh (17.019 kWh/day) 7.401 MWh (20.276 kWh/day) 1.189 MWh (3.257 kWh/day)
Lifetime Since PTO 35.029 MWh (17.657 kW/day) 38.279 MWh (19.295 kW/day) 3.250 MWh (1.638 kW/day)
Lifetime Since Install 35.063 MWh 38.859 MWh 3.796 MWh
Voltage/Current 252.5 V / 0.0 A 252.5 V / 1.8 A 252.5 V / 1.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/01/2021 20:26 (14.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.813 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.269 1.754 1.583 10.065 0.000 kW
1.696 kWh
0.000 kW
10.178 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.260 1.703 1.547 9.757
03 - 202224****** IQ7+M [0] ---- 0.000 0.267 1.703 1.578 9.907
04 - 202232****** IQ7+ [0] ---- 0.000 0.265 1.711 1.557 9.927
05 - 202244****** IQ7+M [0] ---- 0.000 0.261 1.603 1.527 9.241
06 - 202245****** IQ7+M [0] ---- 0.000 0.261 1.704 1.543 9.789
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.265 1.591 1.427 9.154 0.000 kW
1.622 kWh
0.000 kW
8.111 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.265 1.609 1.541 9.358
09 - 202217****** IQ7+ [0] ---- 0.000 0.265 1.620 1.501 9.315
10 - 202244****** IQ7+M [0] ---- 0.000 0.267 1.646 1.556 9.479
11 - 202224****** IQ7+M [0] ---- 0.000 0.268 1.646 1.571 9.497
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.260 1.639 1.353 9.616 0.000 kW
1.631 kWh
0.000 kW
6.524 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.257 1.602 1.276 9.304
14 - 202216****** IQ7+ [0] ---- 0.000 0.260 1.652 1.364 9.638
15 - 202245****** IQ7+M [0] ---- 0.000 0.257 1.632 1.339 9.510
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.