Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.282 kW
01/17/2025 15:32 (1696 days) Production Consumption NET Usage
Now 0.368 kW 0.086 kW -0.282 kW
Today 12.660 kWh (0.814 kW) 8.889 kWh (0.572 kW) -3.771 kWh (-0.243 kW)
  - This Week 68.060 kWh (12.051 kWh/day) 178.596 kWh (31.624 kWh/day) 110.536 kWh (19.572 kWh/day)
  - This Month 172.797 kWh (10.380 kWh/day) 439.586 kWh (26.405 kWh/day) 266.789 kWh (16.026 kWh/day)
  - This Year 0.173 MWh (10.380 kWh/day) 0.440 MWh (26.405 kWh/day) 0.267 MWh (16.026 kWh/day)
Yesterday 7.632 kWh (0.318 kW) 55.288 kWh (2.304 kW) 47.656 kWh (1.986 kW)
Last 7 Days 72.337 kWh (10.334 kWh/day) 212.974 kWh (30.424 kWh/day) 140.637 kWh (20.091 kWh/day)
Last 30 Days 251.946 kWh (8.398 kWh/day) 768.107 kWh (25.604 kWh/day) 516.161 kWh (17.206 kWh/day)
Last One Year 6.757 MWh (18.512 kWh/day) 6.391 MWh (17.509 kWh/day) -0.366 MWh (-1.003 kWh/day)
Lifetime Since PTO 29.624 MWh (17.460 kW/day) 32.392 MWh (19.091 kW/day) 2.769 MWh (1.632 kW/day)
Lifetime Since Install 29.658 MWh 32.972 MWh 3.315 MWh
Voltage/Current 249.8 V / 1.5 A 249.8 V / 0.3 A 249.8 V / -1.1 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 08/19/2020 23:00 (13.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.851 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.260 0.917 1.960 9.115 0.000 kW
0.912 kWh
0.000 kW
5.471 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.257 0.907 1.915 8.903
03 - 202224101754 IQ7+M VCOP 0.000 0.259 0.924 1.951 9.078
04 - 202232127100 IQ7+ VCOP 0.000 0.258 0.913 1.970 9.126
05 - 202244171601 IQ7+M VCOP 0.000 0.259 0.905 1.809 8.407
06 - 202245013024 IQ7+M VCOP 0.000 0.257 0.906 1.882 8.789
front 07 - 202206091803 IQ7+ VCOP 0.000 0.290 0.890 1.841 8.247 0.000 kW
0.931 kWh
0.000 kW
4.654 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.289 0.961 1.850 8.221
09 - 202217001404 IQ7+ VCOP 0.000 0.287 0.891 1.839 8.263
10 - 202244165234 IQ7+M VCOP 0.000 0.287 0.945 1.893 8.416
11 - 202224104308 IQ7+M VCOP 0.000 0.287 0.966 1.890 8.396
back 12 - 202211186551 IQ7+ VCOP 0.000 0.204 0.692 1.852 9.102 0.000 kW
0.682 kWh
0.000 kW
2.727 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.206 0.637 1.761 8.972
14 - 202216155993 IQ7+ VCOP 0.000 0.206 0.705 1.842 9.153
15 - 202245015670 IQ7+M VCOP 0.000 0.203 0.693 1.807 9.022
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 52.48 V Current/Power 163.88 A (8.600 kW)
Remain Capacity/Energy 324.9 Ah (16.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 56.3 % State Of Health 96.2 %
Run Time 1h 32m to full Report Date 2020-08-19 23:42
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.48 V Cell (MIN/MAX) 3.274 V / 3.284 V (0.010 V)
Current/Power -0.51 A (-26 W) Runtime 8d 22h 1m to empty
Remain Capacity/Energy 108.3 Ah (5.5 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 56.3 % State Of Health 96.2 %
Temperature 24.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-19 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.274 V 3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.281 V 3.281 V 3.282 V 3.283 V 3.283 V 3.284 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -