Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.005 kW
01/17/2025 16:26 (1696 days) Production Consumption NET Usage
Now 0.070 kW 0.065 kW -0.005 kW
Today 12.944 kWh (0.787 kW) 9.797 kWh (0.595 kW) -3.147 kWh (-0.191 kW)
  - This Week 68.344 kWh (12.021 kWh/day) 179.504 kWh (31.572 kWh/day) 111.160 kWh (19.551 kWh/day)
  - This Month 173.081 kWh (10.373 kWh/day) 440.494 kWh (26.400 kWh/day) 267.413 kWh (16.027 kWh/day)
  - This Year 0.173 MWh (10.373 kWh/day) 0.440 MWh (26.400 kWh/day) 0.267 MWh (16.027 kWh/day)
Yesterday 7.632 kWh (0.318 kW) 55.288 kWh (2.304 kW) 47.656 kWh (1.986 kW)
Last 7 Days 72.337 kWh (10.334 kWh/day) 212.974 kWh (30.424 kWh/day) 140.637 kWh (20.091 kWh/day)
Last 30 Days 251.946 kWh (8.398 kWh/day) 768.107 kWh (25.604 kWh/day) 516.161 kWh (17.206 kWh/day)
Last One Year 6.757 MWh (18.512 kWh/day) 6.391 MWh (17.509 kWh/day) -0.366 MWh (-1.003 kWh/day)
Lifetime Since PTO 29.624 MWh (17.459 kW/day) 32.393 MWh (19.092 kW/day) 2.769 MWh (1.632 kW/day)
Lifetime Since Install 29.658 MWh 32.973 MWh 3.315 MWh
Voltage/Current 249.8 V / 0.3 A 249.9 V / 0.3 A 249.8 V / -0.0 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 08/28/2020 22:24 (12.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.945 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.295 1.601 1.746 12.350 0.000 kW
1.571 kWh
0.000 kW
9.427 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.291 1.574 1.721 12.147
03 - 202224101754 IQ7+M VCOP 0.000 0.292 1.607 1.745 12.372
04 - 202232127100 IQ7+ VCOP 0.000 0.291 1.613 1.732 12.401
05 - 202244171601 IQ7+M VCOP 0.000 0.293 1.504 1.711 11.710
06 - 202245013024 IQ7+M VCOP 0.000 0.291 1.528 1.718 11.959
front 07 - 202206091803 IQ7+ VCOP 0.000 0.295 1.536 1.743 11.976 0.000 kW
1.534 kWh
0.000 kW
7.670 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.297 1.504 1.764 11.937
09 - 202217001404 IQ7+ VCOP 0.000 0.297 1.535 1.743 11.987
10 - 202244165234 IQ7+M VCOP 0.000 0.295 1.552 1.782 12.215
11 - 202224104308 IQ7+M VCOP 0.000 0.294 1.544 1.773 12.211
back 12 - 202211186551 IQ7+ VCOP 0.000 0.253 1.473 1.385 10.922 0.000 kW
1.462 kWh
0.000 kW
5.848 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.252 1.455 1.339 10.616
14 - 202216155993 IQ7+ VCOP 0.000 0.252 1.473 1.389 10.934
15 - 202245015670 IQ7+M VCOP 0.000 0.246 1.446 1.366 10.760
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 54.49 V Current/Power 173.50 A (9.453 kW)
Remain Capacity/Energy 591.0 Ah (30.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Run Time - to full Report Date 2020-08-28 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 54.49 V Cell (MIN/MAX) 3.355 V / 3.535 V (0.180 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 197.0 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Temperature 27.0 °C Cycle 25
MOSFET CFET = OFF, DFET = ON Reported 2020-08-28 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.379 V 3.520 V 3.396 V 3.534 V 3.361 V 3.535 V 3.355 V 3.382 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.376 V 3.379 V 3.364 V 3.415 V 3.406 V 3.357 V 3.357 V 3.362 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -