Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.204 kW
03/16/2026 09:47 (2119 days) Production Consumption NET Usage
Now 0.481 kW 0.277 kW -0.204 kW
Today 0.387 kWh (0.039 kW) 5.352 kWh (0.546 kW) 4.965 kWh (0.507 kW)
  - This Week 12.276 kWh (8.719 kWh/day) 18.226 kWh (12.944 kWh/day) 5.950 kWh (4.226 kWh/day)
  - This Month 246.997 kWh (16.030 kWh/day) 222.253 kWh (14.425 kWh/day) -24.744 kWh (-1.606 kWh/day)
  - This Year 0.881 MWh (11.839 kWh/day) 1.322 MWh (17.768 kWh/day) 0.441 MWh (5.929 kWh/day)
Yesterday 11.889 kWh (0.495 kW) 12.874 kWh (0.537 kW) 0.985 kWh (0.041 kW)
Last 7 Days 141.332 kWh (20.190 kWh/day) 98.869 kWh (14.124 kWh/day) -42.463 kWh (-6.066 kWh/day)
Last 30 Days (02/14/2026) 409.481 kWh (13.649 kWh/day) 455.564 kWh (15.185 kWh/day) 46.083 kWh (1.536 kWh/day)
Last One Year 6.058 MWh (16.597 kWh/day) 7.841 MWh (21.482 kWh/day) 1.783 MWh (4.885 kWh/day)
Lifetime Since PTO 36.447 MWh (17.197 kW/day) 40.833 MWh (19.266 kW/day) 4.386 MWh (2.070 kW/day)
Lifetime Since Install 36.481 MWh 41.413 MWh 4.932 MWh
Voltage/Current 249.7 V / 1.9 A 249.7 V / 1.1 A 249.7 V / -0.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/29/2021 22:17 (9.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.106 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.577 0.157 4.252 0.000 kW
0.571 kWh
0.000 kW
3.428 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.214 0.545 0.139 4.005
03 - 202224****** IQ7+M [5] VCOP 0.000 0.220 0.596 0.157 4.260
04 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.579 0.150 4.127
05 - 202244****** IQ7+M [5] VCOP 0.000 0.219 0.580 0.143 4.121
06 - 202245****** IQ7+M [5] VCOP 0.000 0.218 0.551 0.148 4.079
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.262 0.632 0.144 4.719 0.000 kW
0.629 kWh
0.000 kW
3.143 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.260 0.533 0.143 4.243
09 - 202217****** IQ7+ [5] VCOP 0.000 0.261 0.682 0.145 4.989
10 - 202244****** IQ7+M [5] VCOP 0.000 0.262 0.659 0.145 4.865
11 - 202224****** IQ7+M [5] VCOP 0.000 0.262 0.637 0.145 4.704
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.129 0.373 0.152 2.381 0.000 kW
0.384 kWh
0.000 kW
1.534 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.385 0.153 2.513
14 - 202216****** IQ7+ [5] VCOP 0.000 0.129 0.392 0.156 2.540
15 - 202245****** IQ7+M [5] VCOP 0.000 0.127 0.384 0.154 2.492
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production