Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.066 kW
01/30/2026 05:36 (2074 days) Production Consumption NET Usage
Now 0.317 kW 0.383 kW 0.066 kW
Today 1.778 kWh (0.317 kW) 2.322 kWh (0.414 kW) 0.544 kWh (0.097 kW)
  - This Week 8.366 kWh (1.598 kWh/day) 69.776 kWh (13.331 kWh/day) 61.410 kWh (11.732 kWh/day)
  - This Month 214.264 kWh (7.329 kWh/day) 554.006 kWh (18.951 kWh/day) 339.742 kWh (11.621 kWh/day)
  - This Year 0.214 MWh (7.329 kWh/day) 0.554 MWh (18.951 kWh/day) 0.340 MWh (11.621 kWh/day)
Yesterday 5.645 kWh (0.235 kW) 11.666 kWh (0.486 kW) 6.021 kWh (0.251 kW)
Last 7 Days 28.266 kWh (4.037 kWh/day) 129.177 kWh (18.451 kWh/day) 100.911 kWh (14.414 kWh/day)
Last 30 Days 222.476 kWh (7.416 kWh/day) 568.292 kWh (18.943 kWh/day) 345.816 kWh (11.527 kWh/day)
Last One Year 6.080 MWh (16.658 kWh/day) 7.497 MWh (20.540 kWh/day) 1.417 MWh (3.881 kWh/day)
Lifetime Since PTO 35.780 MWh (17.249 kW/day) 40.065 MWh (19.315 kW/day) 4.286 MWh (2.066 kW/day)
Lifetime Since Install 35.814 MWh 40.645 MWh 4.832 MWh
Voltage/Current 250.1 V / 1.3 A 250.0 V / 1.5 A 250.1 V / 0.3 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/25/2021 21:02 (10.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.234 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.234 0.650 0.649 7.321 0.000 kW
0.632 kWh
0.000 kW
3.790 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.221 0.613 0.622 6.957
03 - 202224****** IQ7+M [0] ---- 0.000 0.236 0.645 0.643 7.248
04 - 202232****** IQ7+ [0] ---- 0.000 0.242 0.628 0.632 7.068
05 - 202244****** IQ7+M [0] ---- 0.000 0.231 0.627 0.616 7.137
06 - 202245****** IQ7+M [0] ---- 0.000 0.232 0.626 0.622 7.028
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.264 0.650 0.568 7.866 0.000 kW
0.651 kWh
0.000 kW
3.256 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.255 0.639 0.516 7.065
09 - 202217****** IQ7+ [0] ---- 0.000 0.254 0.659 0.631 8.274
10 - 202244****** IQ7+M [0] ---- 0.000 0.252 0.656 0.632 8.201
11 - 202224****** IQ7+M [0] ---- 0.000 0.254 0.651 0.598 8.103
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.152 0.540 0.588 4.931 0.000 kW
0.547 kWh
0.000 kW
2.188 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.156 0.544 0.588 5.032
14 - 202216****** IQ7+ [0] ---- 0.000 0.158 0.556 0.598 5.111
15 - 202245****** IQ7+M [0] ---- 0.000 0.157 0.548 0.589 5.028
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.16 V Current/Power -4.79 A (-0.255 kW)
Remain Capacity/Energy 468.0 Ah (24.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 78.0 % State Of Health 100.0 %
Run Time 4d 1h 42m to empty Report Date 2021-10-25 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.