Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.019 kW
09/25/2024 09:26 (1582 days) Production Consumption NET Usage
Now 0.247 kW 0.228 kW -0.019 kW
Today 0.356 kWh (0.038 kW) 3.392 kWh (0.358 kW) 3.036 kWh (0.321 kW)
  - This Week 43.808 kWh (12.909 kWh/day) 28.378 kWh (8.362 kWh/day) -15.430 kWh (-4.547 kWh/day)
  - This Month 557.179 kWh (22.840 kWh/day) 308.659 kWh (12.653 kWh/day) -248.520 kWh (-10.187 kWh/day)
  - This Year 5.455 MWh (20.326 kWh/day) 4.752 MWh (17.705 kWh/day) -0.704 MWh (-2.621 kWh/day)
Yesterday 10.320 kWh (0.430 kW) 10.385 kWh (0.433 kW) 0.065 kWh (0.003 kW)
Last 7 Days 117.193 kWh (16.744 kWh/day) 68.034 kWh (9.720 kWh/day) -49.159 kWh (-7.023 kWh/day)
Last 30 Days 669.888 kWh (22.330 kWh/day) 389.887 kWh (12.996 kWh/day) -280.001 kWh (-9.333 kWh/day)
Last One Year 6.589 MWh (18.052 kWh/day) 6.447 MWh (17.662 kWh/day) -0.142 MWh (-0.390 kWh/day)
Lifetime Since PTO 28.178 MWh (17.807 kW/day) 30.431 MWh (19.231 kW/day) 2.253 MWh (1.424 kW/day)
Lifetime Since Install 28.212 MWh 31.011 MWh 2.799 MWh
Voltage/Current 247.8 V / 1.0 A 247.6 V / 0.9 A 247.7 V / -0.1 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 07/06/2020 20:42 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.431 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.293 1.512 2.262 12.837 0.000 kW
1.424 kWh
0.000 kW
8.542 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.293 1.444 2.213 12.480
03 - 202224101754 IQ7+M VCOP 0.000 0.297 1.425 2.208 12.483
04 - 202232127100 IQ7+ VCOP 0.000 0.295 1.449 2.220 12.506
05 - 202244171601 IQ7+M VCOP 0.000 0.294 1.246 2.019 11.626
06 - 202245013024 IQ7+M VCOP 0.000 0.290 1.467 2.223 12.562
front 07 - 202206091803 IQ7+ VCOP 0.000 0.288 1.230 1.995 11.361 0.000 kW
1.253 kWh
0.000 kW
6.266 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.287 1.261 2.076 11.738
09 - 202217001404 IQ7+ VCOP 0.000 0.285 1.247 2.025 11.561
10 - 202244165234 IQ7+M VCOP 0.000 0.286 1.268 2.077 11.825
11 - 202224104308 IQ7+M VCOP 0.000 0.285 1.259 2.076 11.789
back 12 - 202211186551 IQ7+ VCOP 0.000 0.260 1.660 2.062 12.572 0.000 kW
1.656 kWh
0.000 kW
6.622 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.264 1.652 1.990 12.284
14 - 202216155993 IQ7+ VCOP 0.000 0.264 1.667 2.064 12.612
15 - 202245015670 IQ7+M VCOP 0.000 0.257 1.643 2.027 12.381
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 56.41 V Current/Power 178.54 A (10.071 kW)
Remain Capacity/Energy 577.2 Ah (29.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-06 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.41 V Cell (MIN/MAX) 3.463 V / 3.589 V (0.126 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 192.4 Ah (9.9 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 23
MOSFET CFET = OFF, DFET = ON Reported 2020-07-06 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.463 V 3.588 V 3.467 V 3.586 V 3.494 V 3.584 V 3.587 V 3.518 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.464 V 3.578 V 3.489 V 3.589 V 3.500 V 3.512 V 3.495 V 3.487 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -