Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.114 kW
07/01/2025 03:54 (1861 days) Production Consumption NET Usage
Now 0.000 kW 2.114 kW 2.114 kW
Today 0.000 kWh (0.000 kW) 3.252 kWh (0.827 kW) 3.252 kWh (0.827 kW)
  - This Week 57.286 kWh (26.485 kWh/day) 70.934 kWh (32.794 kWh/day) 13.648 kWh (6.310 kWh/day)
  - This Month 0.000 kWh (0.000 kWh/day) 3.252 kWh (19.860 kWh/day) 3.252 kWh (19.860 kWh/day)
  - This Year 3.030 MWh (16.724 kWh/day) 3.130 MWh (17.280 kWh/day) 0.101 MWh (0.556 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.452 kW/day) 35.082 MWh (18.850 kW/day) 2.602 MWh (1.398 kW/day)
Lifetime Since Install 32.515 MWh 35.662 MWh 3.148 MWh
Voltage/Current 251.2 V / 0.0 A 251.2 V / 8.4 A 251.2 V / 8.4 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/16/2021 21:46 (12.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.121 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.067 0.292 6.962 0.000 kW
1.041 kWh
0.000 kW
6.249 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.026 0.276 6.777
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.076 0.290 6.975
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.099 0.287 6.981
05 - 202244****** IQ7+M [0] ---- 0.000 0.299 0.980 0.267 6.541
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.001 0.279 6.669
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.299 0.978 0.258 6.650 0.000 kW
0.980 kWh
0.000 kW
4.902 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 0.950 0.255 6.558
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 0.990 0.260 6.656
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 0.996 0.264 6.779
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 0.987 0.258 6.746
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.293 1.247 0.299 6.416 0.000 kW
1.243 kWh
0.000 kW
4.970 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.295 1.241 0.302 6.306
14 - 202216****** IQ7+ [0] ---- 0.000 0.292 1.248 0.307 6.472
15 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.235 0.301 6.381
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.