Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.168 kW
01/30/2026 04:23 (2074 days) Production Consumption NET Usage
Now 0.316 kW 0.484 kW 0.168 kW
Today 1.391 kWh (0.317 kW) 1.851 kWh (0.422 kW) 0.460 kWh (0.105 kW)
  - This Week 7.979 kWh (1.539 kWh/day) 69.305 kWh (13.371 kWh/day) 61.326 kWh (11.831 kWh/day)
  - This Month 213.877 kWh (7.329 kWh/day) 553.535 kWh (18.967 kWh/day) 339.658 kWh (11.639 kWh/day)
  - This Year 0.214 MWh (7.329 kWh/day) 0.554 MWh (18.967 kWh/day) 0.340 MWh (11.639 kWh/day)
Yesterday 5.645 kWh (0.235 kW) 11.666 kWh (0.486 kW) 6.021 kWh (0.251 kW)
Last 7 Days 28.266 kWh (4.037 kWh/day) 129.177 kWh (18.451 kWh/day) 100.911 kWh (14.414 kWh/day)
Last 30 Days 222.476 kWh (7.416 kWh/day) 568.292 kWh (18.943 kWh/day) 345.816 kWh (11.527 kWh/day)
Last One Year 6.080 MWh (16.658 kWh/day) 7.497 MWh (20.540 kWh/day) 1.417 MWh (3.881 kWh/day)
Lifetime Since PTO 35.780 MWh (17.250 kW/day) 40.065 MWh (19.316 kW/day) 4.285 MWh (2.066 kW/day)
Lifetime Since Install 35.813 MWh 40.645 MWh 4.831 MWh
Voltage/Current 250.3 V / 1.3 A 250.2 V / 1.9 A 250.2 V / 0.7 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/24/2021 20:40 (9.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.279 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.214 1.062 0.923 5.915 0.000 kW
1.035 kWh
0.000 kW
6.209 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.208 0.996 0.882 5.639
03 - 202224****** IQ7+M [0] ---- 0.000 0.213 1.064 0.928 5.911
04 - 202232****** IQ7+ [0] ---- 0.000 0.211 1.036 0.881 5.759
05 - 202244****** IQ7+M [0] ---- 0.000 0.211 1.020 0.910 5.815
06 - 202245****** IQ7+M [0] ---- 0.000 0.209 1.030 0.899 5.688
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.271 1.251 1.017 6.630 0.000 kW
1.244 kWh
0.000 kW
6.218 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.268 1.100 0.840 5.909
09 - 202217****** IQ7+ [0] ---- 0.000 0.269 1.341 1.091 7.031
10 - 202244****** IQ7+M [0] ---- 0.000 0.267 1.288 1.063 6.852
11 - 202224****** IQ7+M [0] ---- 0.000 0.267 1.238 0.995 6.611
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.100 0.422 0.463 3.095 0.000 kW
0.463 kWh
0.000 kW
1.853 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.102 0.481 0.496 3.352
14 - 202216****** IQ7+ [0] ---- 0.000 0.102 0.480 0.499 3.352
15 - 202245****** IQ7+M [0] ---- 0.000 0.101 0.470 0.482 3.286
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.23 V Current/Power -2.10 A (-0.112 kW)
Remain Capacity/Energy 357.9 Ah (18.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 59.7 % State Of Health 100.0 %
Run Time 7d 2h 25m to empty Report Date 2021-11-24 23:59
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.