Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.418 kW
01/16/2025 11:56 (1695 days) Production Consumption NET Usage
Now 1.097 kW 0.679 kW -0.418 kW
Today 3.796 kWh (0.318 kW) 6.586 kWh (0.551 kW) 2.790 kWh (0.234 kW)
  - This Week 51.564 kWh (11.465 kWh/day) 121.005 kWh (26.904 kWh/day) 69.441 kWh (15.439 kWh/day)
  - This Month 156.301 kWh (10.085 kWh/day) 381.995 kWh (24.648 kWh/day) 225.694 kWh (14.563 kWh/day)
  - This Year 0.156 MWh (10.085 kWh/day) 0.382 MWh (24.648 kWh/day) 0.226 MWh (14.563 kWh/day)
Yesterday 14.665 kWh (0.611 kW) 16.490 kWh (0.687 kW) 1.825 kWh (0.076 kW)
Last 7 Days 79.562 kWh (11.366 kWh/day) 181.823 kWh (25.975 kWh/day) 102.261 kWh (14.609 kWh/day)
Last 30 Days 254.682 kWh (8.489 kWh/day) 725.467 kWh (24.182 kWh/day) 470.785 kWh (15.693 kWh/day)
Last One Year 6.752 MWh (18.499 kWh/day) 6.367 MWh (17.445 kWh/day) -0.384 MWh (-1.053 kWh/day)
Lifetime Since PTO 29.607 MWh (17.462 kW/day) 32.335 MWh (19.070 kW/day) 2.728 MWh (1.609 kW/day)
Lifetime Since Install 29.641 MWh 32.915 MWh 3.274 MWh
Voltage/Current 250.7 V / 4.4 A 250.6 V / 2.7 A 250.7 V / -1.7 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 12/22/2020 20:38 (8.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.845 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.089 0.098 0.008 1.118 0.000 kW
0.326 kWh
0.000 kW
1.953 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.172 0.166 0.009 1.075
03 - 202224101754 IQ7+M VCOP 0.000 0.198 0.260 0.022 1.072
04 - 202232127100 IQ7+ VCOP 0.000 0.198 0.332 0.024 1.018
05 - 202244171601 IQ7+M VCOP 0.000 0.192 0.526 0.298 1.399
06 - 202245013024 IQ7+M VCOP 0.000 0.192 0.571 0.369 1.509
front 07 - 202206091803 IQ7+ VCOP 0.000 0.273 0.703 0.517 1.845 0.000 kW
0.699 kWh
0.000 kW
3.493 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.275 0.658 0.100 0.149
09 - 202217001404 IQ7+ VCOP 0.000 0.272 0.718 0.816 2.279
10 - 202244165234 IQ7+M VCOP 0.000 0.275 0.718 0.823 2.370
11 - 202224104308 IQ7+M VCOP 0.000 0.271 0.696 0.301 1.648
back 12 - 202211186551 IQ7+ VCOP 0.000 0.097 0.324 0.237 1.271 0.000 kW
0.350 kWh
0.000 kW
1.399 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.108 0.360 0.276 1.142
14 - 202216155993 IQ7+ VCOP 0.000 0.105 0.362 0.275 1.113
15 - 202245015670 IQ7+M VCOP 0.000 0.102 0.352 0.268 1.931
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 51.98 V Current/Power 162.28 A (8.435 kW)
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Run Time 2h 26m to full Report Date 2020-12-22 15:35
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 51.98 V Cell (MIN/MAX) 3.241 V / 3.254 V (0.013 V)
Current/Power -0.50 A (-26 W) Runtime 5d 8h 30m to empty
Remain Capacity/Energy 64.5 Ah (3.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-22 15:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.241 V 3.242 V 3.244 V 3.244 V 3.249 V 3.245 V 3.249 V 3.249 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.248 V 3.251 V 3.249 V 3.252 V 3.253 V 3.254 V 3.254 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -