| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 0.244 kW | |||
|---|---|---|---|
| 08/01/2026 04:55 (2257 days) | Production | Consumption | NET Usage |
| Now | 0.000 kW | 0.244 kW | 0.244 kW |
| Today | 0.000 kWh (0.000 kW) | 2.483 kWh (0.504 kW) | 2.483 kWh (0.504 kW) |
| - This Week | 124.647 kWh (20.084 kWh/day) | 139.256 kWh (22.438 kWh/day) | 14.609 kWh (2.354 kWh/day) |
| - This Month | 0.000 kWh (0.000 kWh/day) | 2.483 kWh (12.101 kWh/day) | 2.483 kWh (12.101 kWh/day) |
| - This Year | 4.406 MWh (20.762 kWh/day) | 4.173 MWh (19.664 kWh/day) | -0.233 MWh (-1.098 kWh/day) |
| Yesterday | 22.669 kWh (0.944 kW) | 14.942 kWh (0.622 kW) | -7.727 kWh (-0.322 kW) |
| Last 7 Days | 155.996 kWh (22.285 kWh/day) | 150.669 kWh (21.524 kWh/day) | -5.327 kWh (-0.761 kWh/day) |
| Last 30 Days (07/02/2026) | 769.369 kWh (25.646 kWh/day) | 836.495 kWh (27.883 kWh/day) | 67.126 kWh (2.238 kWh/day) |
| Last One Year | 6.763 MWh (18.528 kWh/day) | 7.392 MWh (20.252 kWh/day) | 0.629 MWh (1.724 kWh/day) |
| Lifetime Since PTO | 39.971 MWh (17.708 kW/day) | 43.684 MWh (19.353 kW/day) | 3.712 MWh (1.645 kW/day) |
| Lifetime Since Install | 40.005 MWh | 44.263 MWh | 4.258 MWh |
| Voltage/Current | 250.9 V / 0.0 A | 250.8 V / 1.0 A | 250.9 V / 1.0 A |
|
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 07/09/2022 23:11 (14.6 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 30.429 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.294 | 2.157 | 1.231 | 12.079 | 0.000 kW 2.053 kWh |
0.000 kW 12.316 kWh |
| 02 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.287 | 2.039 | 1.125 | 11.430 | |||
| 03 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.291 | 2.068 | 1.205 | 11.843 | |||
| 04 - 202232****** | IQ7+ | [0] ---- | 0.000 | 0.293 | 2.070 | 1.162 | 11.606 | |||
| 05 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.287 | 1.908 | 1.136 | 11.079 | |||
| 06 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.282 | 2.074 | 1.144 | 11.543 | |||
| front | 07 - 202206****** | IQ7+ | [0] ---- | 0.000 | 0.284 | 1.961 | 1.095 | 10.970 | 0.000 kW 1.944 kWh |
0.000 kW 9.718 kWh |
| 08 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.288 | 1.869 | 1.084 | 10.653 | |||
| 09 - 202217****** | IQ7+ | [0] ---- | 0.000 | 0.282 | 1.917 | 1.088 | 10.729 | |||
| 10 - 202244****** | IQ7+M | [0] ---- | 0.000 | 0.283 | 1.979 | 1.101 | 11.024 | |||
| 11 - 202224****** | IQ7+M | [0] ---- | 0.000 | 0.282 | 1.992 | 1.086 | 11.143 | |||
| back | 12 - 202211****** | IQ7+ | [0] ---- | 0.000 | 0.263 | 2.120 | 1.265 | 11.539 | 0.000 kW 2.099 kWh |
0.000 kW 8.394 kWh |
| 13 - 202223****** | IQ7+ | [0] ---- | 0.000 | 0.262 | 2.039 | 1.254 | 11.189 | |||
| 14 - 202216****** | IQ7+ | [0] ---- | 0.000 | 0.265 | 2.134 | 1.285 | 11.634 | |||
| 15 - 202245****** | IQ7+M | [0] ---- | 0.000 | 0.260 | 2.102 | 1.263 | 11.418 | |||
| yard | 16 - 122344****** | IQ7AS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| battery | 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
|
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.21 V | Current/Power | -1.50 A (-79 W) |
| Remain Capacity/Energy | 526.5 Ah (27.0 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 87.8 % | State Of Health | 100.0 % |
| Run Time | 14d 15h 0m to empty | Report Date | 2022-07-09 23:51 |
|
|
|||
| Voltage | 53.24 V | Cell (MIN/MAX) | 3.322 V / 3.331 V (0.009 V) |
|---|---|---|---|
| Current/Power | -0.46 A (-24 W) | Runtime | 16d 0h 52m to empty |
| Remain Capacity/Energy | 175.5 Ah (9.0 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 87.8 % | State Of Health | 100.0 % |
| Temperature | 25.0 °C | Cycle | 69 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-07-09 23:51 |
| Voltage | 53.20 V | Cell (MIN/MAX) | 3.324 V / 3.325 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 24.4 °C | Cycle | 20 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-07-09 23:58 |
| Voltage | 53.23 V | Cell (MIN/MAX) | 3.326 V / 3.328 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 25.9 °C | Cycle | 21 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-07-09 23:59 |
| Voltage | 53.18 V | Cell (MIN/MAX) | 3.323 V / 3.324 V (0.001 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.5 Ah (5.1 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 100.0 % |
| Temperature | 26.0 °C | Cycle | 21 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-07-09 23:50 |
| Voltage | 53.20 V | Cell (MIN/MAX) | 3.323 V / 3.325 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.2 Ah (5.1 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.7 % |
| Temperature | 24.5 °C | Cycle | 21 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-07-09 23:54 |