Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 13.182 kW
01/16/2025 17:04 (1695 days) Production Consumption NET Usage
Now 0.000 kW 13.182 kW 13.182 kW
Today 7.632 kWh (0.447 kW) 45.050 kWh (2.636 kW) 37.418 kWh (2.190 kW)
  - This Week 55.400 kWh (11.757 kWh/day) 159.469 kWh (33.843 kWh/day) 104.069 kWh (22.086 kWh/day)
  - This Month 160.137 kWh (10.192 kWh/day) 420.459 kWh (26.760 kWh/day) 260.322 kWh (16.568 kWh/day)
  - This Year 0.160 MWh (10.192 kWh/day) 0.420 MWh (26.760 kWh/day) 0.260 MWh (16.568 kWh/day)
Yesterday 14.665 kWh (0.611 kW) 16.490 kWh (0.687 kW) 1.825 kWh (0.076 kW)
Last 7 Days 79.562 kWh (11.366 kWh/day) 181.823 kWh (25.975 kWh/day) 102.261 kWh (14.609 kWh/day)
Last 30 Days 254.682 kWh (8.489 kWh/day) 725.467 kWh (24.182 kWh/day) 470.785 kWh (15.693 kWh/day)
Last One Year 6.752 MWh (18.499 kWh/day) 6.367 MWh (17.445 kWh/day) -0.384 MWh (-1.053 kWh/day)
Lifetime Since PTO 29.611 MWh (17.462 kW/day) 32.373 MWh (19.091 kW/day) 2.762 MWh (1.629 kW/day)
Lifetime Since Install 29.645 MWh 32.953 MWh 3.308 MWh
Voltage/Current 244.5 V / 0.0 A 244.4 V / 53.9 A 244.4 V / 53.9 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 01/03/2021 20:23 (8.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.697 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.021 0.050 0.700 4.143 0.000 kW
0.047 kWh
0.000 kW
0.285 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.020 0.042 0.669 3.830
03 - 202224101754 IQ7+M ---- 0.000 0.019 0.046 0.682 3.870
04 - 202232127100 IQ7+ ---- 0.000 0.019 0.047 0.661 3.790
05 - 202244171601 IQ7+M ---- 0.000 0.021 0.046 0.698 4.045
06 - 202245013024 IQ7+M ---- 0.000 0.023 0.053 0.713 4.220
front 07 - 202206091803 IQ7+ ---- 0.000 0.018 0.047 0.881 5.166 0.000 kW
0.042 kWh
0.000 kW
0.211 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.017 0.042 0.791 4.638
09 - 202217001404 IQ7+ V--- 0.000 0.016 0.041 0.964 5.495
10 - 202244165234 IQ7+M ---- 0.000 0.017 0.041 0.956 5.466
11 - 202224104308 IQ7+M ---- 0.000 0.017 0.040 0.896 5.130
back 12 - 202211186551 IQ7+ ---- 0.000 0.021 0.053 0.310 2.080 0.000 kW
0.050 kWh
0.000 kW
0.202 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.021 0.050 0.338 2.291
14 - 202216155993 IQ7+ ---- 0.000 0.020 0.050 0.339 2.292
15 - 202245015670 IQ7+M ---- 0.000 0.020 0.049 0.330 2.237
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 53.19 V Current/Power 166.12 A (8.836 kW)
Remain Capacity/Energy 451.8 Ah (23.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 76.4 % State Of Health 98.5 %
Run Time 50m to full Report Date 2021-01-03 23:42
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.19 V Cell (MIN/MAX) 3.318 V / 3.329 V (0.011 V)
Current/Power -0.26 A (-13 W) Runtime 23d 22h 48m to empty
Remain Capacity/Energy 150.6 Ah (7.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 76.4 % State Of Health 98.5 %
Temperature 18.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-03 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.320 V 3.320 V 3.321 V 3.322 V 3.323 V 3.323 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.326 V 3.326 V 3.327 V 3.328 V 3.328 V 3.329 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -