Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.051 kW
01/30/2026 07:29 (2074 days) Production Consumption NET Usage
Now 0.338 kW 0.389 kW 0.051 kW
Today 2.380 kWh (0.318 kW) 3.057 kWh (0.408 kW) 0.677 kWh (0.090 kW)
  - This Week 8.968 kWh (1.688 kWh/day) 70.511 kWh (13.272 kWh/day) 61.543 kWh (11.584 kWh/day)
  - This Month 214.866 kWh (7.330 kWh/day) 554.741 kWh (18.925 kWh/day) 339.875 kWh (11.595 kWh/day)
  - This Year 0.215 MWh (7.330 kWh/day) 0.555 MWh (18.925 kWh/day) 0.340 MWh (11.595 kWh/day)
Yesterday 5.645 kWh (0.235 kW) 11.666 kWh (0.486 kW) 6.021 kWh (0.251 kW)
Last 7 Days 28.266 kWh (4.037 kWh/day) 129.177 kWh (18.451 kWh/day) 100.911 kWh (14.414 kWh/day)
Last 30 Days 222.476 kWh (7.416 kWh/day) 568.292 kWh (18.943 kWh/day) 345.816 kWh (11.527 kWh/day)
Last One Year 6.080 MWh (16.658 kWh/day) 7.497 MWh (20.540 kWh/day) 1.417 MWh (3.881 kWh/day)
Lifetime Since PTO 35.781 MWh (17.249 kW/day) 40.066 MWh (19.315 kW/day) 4.286 MWh (2.066 kW/day)
Lifetime Since Install 35.814 MWh 40.646 MWh 4.832 MWh
Voltage/Current 248.8 V / 1.4 A 248.9 V / 1.6 A 248.9 V / 0.2 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/31/2022 22:26 (9.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.787 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.247 1.139 0.389 4.596 0.000 kW
0.862 kWh
0.000 kW
5.169 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.125 0.448 0.073 4.061
03 - 202224****** IQ7+M [5] VCOP 0.000 0.244 0.901 0.154 4.368
04 - 202232****** IQ7+ [5] VCOP 0.000 0.189 0.599 0.079 4.199
05 - 202244****** IQ7+M [5] VCOP 0.000 0.245 1.135 0.383 4.506
06 - 202245****** IQ7+M [5] VC-- 0.000 0.240 0.947 0.215 4.188
front 07 - 202206****** IQ7+ [5] VC-- 0.000 0.296 1.409 0.735 5.630 0.000 kW
1.410 kWh
0.000 kW
7.052 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.303 0.706 5.190
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.488 0.731 5.934
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.456 0.743 5.826
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.396 0.503 5.459
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.160 0.605 0.501 2.761 0.000 kW
0.642 kWh
0.000 kW
2.566 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.161 0.653 0.687 3.247
14 - 202216****** IQ7+ [0] ---- 0.000 0.163 0.662 0.691 3.255
15 - 202245****** IQ7+M [0] ---- 0.000 0.161 0.647 0.675 3.179
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.16 V Current/Power -4.56 A (-0.242 kW)
Remain Capacity/Energy 514.8 Ah (26.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.8 % State Of Health 100.0 %
Run Time 4d 16h 53m to empty Report Date 2022-01-31 23:51
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.