Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.246 kW
01/07/2025 14:40 (1686 days) Production Consumption NET Usage
Now 2.109 kW 0.863 kW -1.246 kW
Today 13.917 kWh (0.948 kW) 10.998 kWh (0.749 kW) -2.919 kWh (-0.199 kW)
  - This Week 25.092 kWh (9.604 kWh/day) 54.552 kWh (20.880 kWh/day) 29.460 kWh (11.276 kWh/day)
  - This Month 58.211 kWh (8.804 kWh/day) 160.325 kWh (24.248 kWh/day) 102.114 kWh (15.444 kWh/day)
  - This Year 0.058 MWh (8.804 kWh/day) 0.160 MWh (24.248 kWh/day) 0.102 MWh (15.444 kWh/day)
Yesterday 2.184 kWh (0.091 kW) 22.828 kWh (0.951 kW) 20.644 kWh (0.860 kW)
Last 7 Days 55.203 kWh (7.886 kWh/day) 166.132 kWh (23.732 kWh/day) 110.929 kWh (15.846 kWh/day)
Last 30 Days 213.569 kWh (7.119 kWh/day) 632.199 kWh (21.073 kWh/day) 418.630 kWh (13.954 kWh/day)
Last One Year 6.703 MWh (18.364 kWh/day) 6.283 MWh (17.214 kWh/day) -0.420 MWh (-1.150 kWh/day)
Lifetime Since PTO 29.509 MWh (17.496 kW/day) 32.113 MWh (19.040 kW/day) 2.604 MWh (1.544 kW/day)
Lifetime Since Install 29.543 MWh 32.693 MWh 3.150 MWh
Voltage/Current 250.5 V / 8.4 A 250.4 V / 3.4 A 250.5 V / -5.0 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 08/14/2024 23:04 (21.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.580 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ VCOP 0.000 0.286 1.812 1.993 8.516 0.000 kW
1.732 kWh
0.000 kW
10.389 kWh
02 - 202244177619 IQ7+M VCOP 0.000 0.275 1.699 1.874 7.985
03 - 202224101754 IQ7+M VCOP 0.000 0.287 1.769 1.943 8.315
04 - 202232127100 IQ7+ VCOP 0.000 0.291 1.802 1.983 8.450
05 - 202244171601 IQ7+M VCOP 0.000 0.273 1.594 1.763 7.529
06 - 202245013024 IQ7+M VCOP 0.000 0.282 1.714 1.886 8.056
front 07 - 202206091803 IQ7+ VCOP 0.000 0.286 1.693 1.884 7.931 0.000 kW
1.700 kWh
0.000 kW
8.499 kWh
08 - 202245013989 IQ7+M VCOP 0.000 0.292 1.691 1.850 7.864
09 - 202217001404 IQ7+ VCOP 0.000 0.284 1.675 1.840 7.845
10 - 202244165234 IQ7+M VCOP 0.000 0.283 1.701 1.902 7.990
11 - 202224104308 IQ7+M VCOP 0.000 0.290 1.739 1.928 8.131
back 12 - 202211186551 IQ7+ VCOP 0.000 0.245 1.603 1.785 7.656 0.000 kW
1.659 kWh
0.000 kW
6.636 kWh
13 - 202223042463 IQ7+ VCOP 0.000 0.252 1.640 1.787 7.749
14 - 202216155993 IQ7+ VCOP 0.000 0.253 1.699 1.885 8.193
15 - 202245015670 IQ7+M VCOP 0.000 0.259 1.695 1.874 8.157
wind 16 - 122214035120 IQ7PD ---- 0.000 0.246 5.056 5.497 18.214 0.000 kW
5.056 kWh
0.000 kW
5.056 kWh
Panel Layout Each Group Production

Battery History
Voltage 51.61 V Current/Power -3.00 A (-0.155 kW)
Remain Capacity/Energy 79.5 Ah (4.1 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 13.4 % State Of Health 98.9 %
Run Time 1d 2h 30m to empty Report Date 2024-08-14 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.