Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.625 kW
07/05/2025 11:27 (1865 days) Production Consumption NET Usage
Now 3.070 kW 0.445 kW -2.625 kW
Today 7.614 kWh (0.663 kW) 5.926 kWh (0.516 kW) -1.688 kWh (-0.147 kW)
  - This Week 163.883 kWh (25.299 kWh/day) 215.772 kWh (33.309 kWh/day) 51.889 kWh (8.010 kWh/day)
  - This Month 106.597 kWh (23.801 kWh/day) 148.090 kWh (33.066 kWh/day) 41.493 kWh (9.265 kWh/day)
  - This Year 3.136 MWh (16.909 kWh/day) 3.275 MWh (17.659 kWh/day) 0.139 MWh (0.750 kWh/day)
Yesterday 33.170 kWh (1.383 kW) 53.473 kWh (2.229 kW) 20.303 kWh (0.846 kW)
Last 7 Days 177.451 kWh (25.352 kWh/day) 233.676 kWh (33.385 kWh/day) 56.225 kWh (8.033 kWh/day)
Last 30 Days 615.341 kWh (20.511 kWh/day) 853.443 kWh (28.448 kWh/day) 238.102 kWh (7.937 kWh/day)
Last One Year 6.315 MWh (17.302 kWh/day) 6.414 MWh (17.572 kWh/day) 0.098 MWh (0.270 kWh/day)
Lifetime Since PTO 32.587 MWh (17.469 kW/day) 35.227 MWh (18.884 kW/day) 2.640 MWh (1.415 kW/day)
Lifetime Since Install 32.621 MWh 35.807 MWh 3.186 MWh
Voltage/Current 248.7 V / 12.3 A 248.6 V / 1.8 A 248.6 V / -10.6 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/25/2021 23:47 (13.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.312 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.843 2.019 7.364 0.000 kW
1.799 kWh
0.000 kW
10.794 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.790 1.951 5.143
03 - 202224****** IQ7+M [5] VCOP 0.000 0.286 1.844 2.000 7.341
04 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.869 2.017 7.339
05 - 202244****** IQ7+M [5] VCOP 0.000 0.279 1.707 1.874 7.012
06 - 202245****** IQ7+M [5] VCOP 0.000 0.274 1.742 1.915 6.619
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.794 1.958 7.073 0.000 kW
1.794 kWh
0.000 kW
8.972 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.764 1.961 7.116
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.773 1.946 7.083
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.811 1.990 7.182
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.828 2.019 7.236
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.219 1.652 1.740 6.504 0.000 kW
1.637 kWh
0.000 kW
6.546 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.220 1.596 1.655 6.315
14 - 202216****** IQ7+ [5] VCOP 0.000 0.222 1.662 1.736 6.586
15 - 202245****** IQ7+M [5] VCOP 0.000 0.219 1.636 1.702 6.483
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.25 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 496.5 Ah (25.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.8 % State Of Health 100.0 %
Run Time 13d 19h 0m to empty Report Date 2021-08-25 23:58
voltag, current for each battery pack voltage, current, and SOC


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.