| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Importing from grid by 1.629 kW | |||
|---|---|---|---|
| 06/27/2026 17:01 (2222 days) | Production | Consumption | NET Usage |
| Now | 0.637 kW | 2.266 kW | 1.629 kW |
| Today | 9.041 kWh (0.530 kW) | 8.826 kWh (0.518 kW) | -0.215 kWh (-0.013 kW) |
| - This Week | 133.204 kWh (19.853 kWh/day) | 147.712 kWh (22.015 kWh/day) | 14.508 kWh (2.162 kWh/day) |
| - This Month | 792.850 kWh (29.683 kWh/day) | 634.568 kWh (23.757 kWh/day) | -158.282 kWh (-5.926 kWh/day) |
| - This Year | 3.527 MWh (19.848 kWh/day) | 3.205 MWh (18.032 kWh/day) | -0.323 MWh (-1.816 kWh/day) |
| Yesterday | 18.889 kWh (0.787 kW) | 17.732 kWh (0.739 kW) | -1.157 kWh (-0.048 kW) |
| Last 7 Days | 137.051 kWh (19.579 kWh/day) | 157.070 kWh (22.439 kWh/day) | 20.019 kWh (2.860 kWh/day) |
| Last 30 Days (05/28/2026) | 895.535 kWh (29.851 kWh/day) | 714.497 kWh (23.817 kWh/day) | -181.038 kWh (-6.035 kWh/day) |
| Last One Year | 6.692 MWh (18.333 kWh/day) | 7.734 MWh (21.190 kWh/day) | 1.043 MWh (2.856 kWh/day) |
| Lifetime Since PTO | 39.093 MWh (17.588 kW/day) | 42.715 MWh (19.218 kW/day) | 3.622 MWh (1.630 kW/day) |
| Lifetime Since Install | 39.127 MWh | 43.295 MWh | 4.168 MWh |
| Voltage/Current | 249.6 V / 2.6 A | 249.4 V / 9.1 A | 249.5 V / 6.5 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 08/24/2022 22:21 (13.1 hours) | Number of Devices | 18 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 27.262 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.295 | 1.938 | 1.752 | 9.468 | 0.000 kW 1.866 kWh |
0.000 kW 11.196 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.293 | 1.838 | 1.649 | 8.945 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.906 | 1.741 | 9.424 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.294 | 1.916 | 1.712 | 9.334 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.792 | 1.627 | 8.843 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.288 | 1.805 | 1.621 | 8.859 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.297 | 1.865 | 1.683 | 8.915 | 0.000 kW 1.869 kWh |
0.000 kW 9.345 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.299 | 1.850 | 1.717 | 8.969 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.298 | 1.817 | 1.686 | 8.831 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.903 | 1.722 | 9.040 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.297 | 1.908 | 1.718 | 9.089 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.248 | 1.719 | 1.489 | 9.000 | 0.000 kW 1.680 kWh |
0.000 kW 6.721 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.246 | 1.637 | 1.407 | 8.742 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.246 | 1.698 | 1.513 | 9.078 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.237 | 1.667 | 1.452 | 8.856 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122344****** | IQ7AS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
| 18 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||
| Battery History | |||
|---|---|---|---|
| Voltage | 53.18 V | Current/Power | -5.03 A (-0.267 kW) |
| Remain Capacity/Energy | 505.5 Ah (25.9 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
| State Of Charge | 84.3 % | State Of Health | 100.0 % |
| Run Time | 4d 4h 30m to empty | Report Date | 2022-08-24 23:58 |
|
|||
| Voltage | 53.21 V | Cell (MIN/MAX) | 3.321 V / 3.330 V (0.009 V) |
|---|---|---|---|
| Current/Power | -1.65 A (-87 W) | Runtime | 4d 6h 3m to empty |
| Remain Capacity/Energy | 168.5 Ah (8.6 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
| State Of Charge | 84.3 % | State Of Health | 100.0 % |
| Temperature | 26.5 °C | Cycle | 75 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-24 23:58 |
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.321 V / 3.323 V (0.002 V) |
|---|---|---|---|
| Current/Power | -0.88 A (-46 W) | Runtime | 4d 11h 13m to empty |
| Remain Capacity/Energy | 94.4 Ah (4.8 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 94.4 % | State Of Health | 100.0 % |
| Temperature | 26.0 °C | Cycle | 25 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-24 23:59 |
| Voltage | 53.21 V | Cell (MIN/MAX) | 3.325 V / 3.326 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.97 A (-51 W) | Runtime | 4d 0h 54m to empty |
| Remain Capacity/Energy | 93.9 Ah (4.8 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 93.9 % | State Of Health | 100.0 % |
| Temperature | 27.1 °C | Cycle | 26 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-24 23:54 |
| Voltage | 53.16 V | Cell (MIN/MAX) | 3.321 V / 3.322 V (0.001 V) |
|---|---|---|---|
| Current/Power | -1.02 A (-54 W) | Runtime | 3d 19h 48m to empty |
| Remain Capacity/Energy | 93.7 Ah (4.8 kWh) | Full Capacity/Energy | 100.0 Ah (5.1 kWh) |
| State Of Charge | 93.7 % | State Of Health | 100.0 % |
| Temperature | 27.1 °C | Cycle | 26 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-24 23:56 |
| Voltage | 53.17 V | Cell (MIN/MAX) | 3.322 V / 3.323 V (0.001 V) |
|---|---|---|---|
| Current/Power | -0.97 A (-51 W) | Runtime | 4d 0h 48m to empty |
| Remain Capacity/Energy | 93.8 Ah (4.8 kWh) | Full Capacity/Energy | 99.7 Ah (5.1 kWh) |
| State Of Charge | 94.1 % | State Of Health | 99.7 % |
| Temperature | 26.0 °C | Cycle | 26 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2022-08-24 23:57 |