Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.659 kW
09/24/2024 19:15 (1581 days) Production Consumption NET Usage
Now 0.000 kW 0.659 kW 0.659 kW
Today 10.320 kWh (0.535 kW) 7.881 kWh (0.409 kW) -2.439 kWh (-0.126 kW)
  - This Week 43.452 kWh (15.504 kWh/day) 22.482 kWh (8.022 kWh/day) -20.970 kWh (-7.482 kWh/day)
  - This Month 556.823 kWh (23.392 kWh/day) 302.763 kWh (12.719 kWh/day) -254.060 kWh (-10.673 kWh/day)
  - This Year 5.455 MWh (20.370 kWh/day) 4.746 MWh (17.722 kWh/day) -0.709 MWh (-2.648 kWh/day)
Yesterday 9.529 kWh (0.397 kW) 10.278 kWh (0.428 kW) 0.749 kWh (0.031 kW)
Last 7 Days 124.566 kWh (17.794 kWh/day) 64.680 kWh (9.239 kWh/day) -59.886 kWh (-8.555 kWh/day)
Last 30 Days 681.482 kWh (22.717 kWh/day) 394.954 kWh (13.165 kWh/day) -286.528 kWh (-9.551 kWh/day)
Last One Year 6.583 MWh (18.035 kWh/day) 6.448 MWh (17.666 kWh/day) -0.135 MWh (-0.369 kWh/day)
Lifetime Since PTO 28.178 MWh (17.814 kW/day) 30.425 MWh (19.234 kW/day) 2.247 MWh (1.421 kW/day)
Lifetime Since Install 28.212 MWh 31.005 MWh 2.793 MWh
Voltage/Current 248.3 V / 0.0 A 248.4 V / 2.7 A 248.3 V / 2.7 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 12/17/2020 21:39 (5.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.282 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.000 0.000 0.190 3.475 0.000 kW
0.001 kWh
0.000 kW
0.004 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.000 0.000 0.179 3.356
03 - 202224101754 IQ7+M ---- 0.000 0.002 0.001 0.189 3.314
04 - 202232127100 IQ7+ ---- 0.000 0.002 0.001 0.186 3.156
05 - 202244171601 IQ7+M ---- 0.000 0.002 0.001 0.174 3.561
06 - 202245013024 IQ7+M ---- 0.000 0.002 0.001 0.180 3.632
front 07 - 202206091803 IQ7+ V--- 0.000 0.005 0.002 0.168 4.225 0.000 kW
0.005 kWh
0.000 kW
0.023 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.004 0.001 0.042 0.042
09 - 202217001404 IQ7+ ---- 0.000 0.005 0.007 0.170 4.528
10 - 202244165234 IQ7+M ---- 0.000 0.006 0.008 0.173 4.481
11 - 202224104308 IQ7+M ---- 0.000 0.005 0.005 0.168 4.148
back 12 - 202211186551 IQ7+ ---- 0.000 0.016 0.050 0.191 1.778 0.000 kW
0.064 kWh
0.000 kW
0.255 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.013 0.040 0.192 1.950
14 - 202216155993 IQ7+ ---- 0.000 0.012 0.036 0.196 1.952
15 - 202245015670 IQ7+M ---- 0.000 0.050 0.130 0.192 1.896
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 52.49 V Current/Power 163.92 A (8.604 kW)
Remain Capacity/Energy 365.4 Ah (18.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 61.8 % State Of Health 98.5 %
Run Time 1h 22m to full Report Date 2020-12-17 23:27
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.49 V Cell (MIN/MAX) 3.275 V / 3.285 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 10d 3h 7m to empty
Remain Capacity/Energy 121.8 Ah (6.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 61.8 % State Of Health 98.5 %
Temperature 22.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-17 23:27
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V 3.280 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.282 V 3.282 V 3.283 V 3.284 V 3.284 V 3.285 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -