Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.344 kW
09/24/2024 21:35 (1581 days) Production Consumption NET Usage
Now 0.000 kW 0.344 kW 0.344 kW
Today 10.320 kWh (0.477 kW) 9.676 kWh (0.448 kW) -0.644 kWh (-0.030 kW)
  - This Week 43.452 kWh (14.984 kWh/day) 24.277 kWh (8.372 kWh/day) -19.175 kWh (-6.612 kWh/day)
  - This Month 556.823 kWh (23.297 kWh/day) 304.558 kWh (12.742 kWh/day) -252.265 kWh (-10.554 kWh/day)
  - This Year 5.455 MWh (20.362 kWh/day) 4.748 MWh (17.722 kWh/day) -0.707 MWh (-2.640 kWh/day)
Yesterday 9.529 kWh (0.397 kW) 10.278 kWh (0.428 kW) 0.749 kWh (0.031 kW)
Last 7 Days 124.566 kWh (17.794 kWh/day) 64.680 kWh (9.239 kWh/day) -59.886 kWh (-8.555 kWh/day)
Last 30 Days 681.482 kWh (22.717 kWh/day) 394.954 kWh (13.165 kWh/day) -286.528 kWh (-9.551 kWh/day)
Last One Year 6.583 MWh (18.035 kWh/day) 6.448 MWh (17.666 kWh/day) -0.135 MWh (-0.369 kWh/day)
Lifetime Since PTO 28.178 MWh (17.813 kW/day) 30.427 MWh (19.234 kW/day) 2.249 MWh (1.422 kW/day)
Lifetime Since Install 28.212 MWh 31.007 MWh 2.795 MWh
Voltage/Current 249.7 V / 0.0 A 249.7 V / 1.4 A 249.7 V / 1.4 A
Meter Accumulated Grid Votlage

Micro-inverters
Recent Report Data/Time 01/04/2021 21:47 (8.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.943 kWh
Group Serial Number Model Status Power (kW) [Flag] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232127871 IQ7+ ---- 0.000 0.212 0.485 0.050 3.271 0.000 kW
0.450 kWh
0.000 kW
2.699 kWh
02 - 202244177619 IQ7+M ---- 0.000 0.203 0.432 0.042 3.021
03 - 202224101754 IQ7+M ---- 0.000 0.206 0.419 0.046 3.083
04 - 202232127100 IQ7+ ---- 0.000 0.173 0.377 0.047 3.036
05 - 202244171601 IQ7+M ---- 0.000 0.204 0.474 0.046 3.163
06 - 202245013024 IQ7+M ---- 0.000 0.204 0.511 0.053 3.298
front 07 - 202206091803 IQ7+ V--- 0.000 0.253 0.609 0.047 3.994 0.000 kW
0.583 kWh
0.000 kW
2.915 kWh
08 - 202245013989 IQ7+M ---- 0.000 0.255 0.484 0.042 3.621
09 - 202217001404 IQ7+ ---- 0.000 0.258 0.619 0.041 4.223
10 - 202244165234 IQ7+M ---- 0.000 0.259 0.619 0.041 4.205
11 - 202224104308 IQ7+M ---- 0.000 0.255 0.583 0.040 3.978
back 12 - 202211186551 IQ7+ ---- 0.000 0.102 0.316 0.053 1.797 0.000 kW
0.332 kWh
0.000 kW
1.329 kWh
13 - 202223042463 IQ7+ ---- 0.000 0.108 0.340 0.050 1.932
14 - 202216155993 IQ7+ ---- 0.000 0.108 0.342 0.050 1.938
15 - 202245015670 IQ7+M ---- 0.000 0.106 0.332 0.049 1.891
wind 16 - 122214035120 IQ7PD ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 215

Battery History
Voltage 53.18 V Current/Power 166.07 A (8.831 kW)
Remain Capacity/Energy 433.8 Ah (22.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 73.4 % State Of Health 98.5 %
Run Time 56m to full Report Date 2021-01-04 23:49
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.18 V Cell (MIN/MAX) 3.317 V / 3.328 V (0.011 V)
Current/Power -0.25 A (-13 W) Runtime 24d 2h 24m to empty
Remain Capacity/Energy 144.6 Ah (7.4 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 73.4 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-04 23:49
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.319 V 3.320 V 3.320 V 3.321 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.325 V 3.326 V 3.326 V 3.327 V 3.327 V 3.328 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -