Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.718 kW
03/14/2026 15:31 (2117 days) Production Consumption NET Usage
Now 3.845 kW 0.127 kW -3.718 kW
Today 25.182 kWh (1.621 kW) 8.052 kWh (0.518 kW) -17.130 kWh (-1.103 kW)
  - This Week 132.016 kWh (19.860 kWh/day) 90.660 kWh (13.639 kWh/day) -41.356 kWh (-6.221 kWh/day)
  - This Month 225.724 kWh (16.540 kWh/day) 196.959 kWh (14.432 kWh/day) -28.765 kWh (-2.108 kWh/day)
  - This Year 0.860 MWh (11.833 kWh/day) 1.297 MWh (17.850 kWh/day) 0.437 MWh (6.017 kWh/day)
Yesterday 20.551 kWh (0.855 kW) 13.313 kWh (0.554 kW) -7.238 kWh (-0.301 kW)
Last 7 Days 133.513 kWh (19.073 kWh/day) 97.466 kWh (13.924 kWh/day) -36.047 kWh (-5.150 kWh/day)
Last 30 Days (02/12/2026) 386.433 kWh (12.881 kWh/day) 492.263 kWh (16.409 kWh/day) 105.830 kWh (3.528 kWh/day)
Last One Year 6.023 MWh (16.500 kWh/day) 7.829 MWh (21.450 kWh/day) 1.807 MWh (4.949 kWh/day)
Lifetime Since PTO 36.425 MWh (17.201 kW/day) 40.808 MWh (19.270 kW/day) 4.382 MWh (2.069 kW/day)
Lifetime Since Install 36.459 MWh 41.388 MWh 4.928 MWh
Voltage/Current 251.7 V / 15.3 A 251.7 V / 0.5 A 251.7 V / -14.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/27/2022 23:18 (14.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.202 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.285 0.652 2.145 11.028 0.000 kW
0.634 kWh
0.000 kW
3.802 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.282 0.616 2.000 10.407
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 0.654 2.059 10.653
04 - 202232****** IQ7+ [5] VCOP 0.000 0.286 0.633 2.049 10.537
05 - 202244****** IQ7+M [5] VCOP 0.000 0.283 0.625 1.861 9.816
06 - 202245****** IQ7+M [5] VCOP 0.000 0.279 0.623 2.046 10.512
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.279 0.575 1.925 9.870 0.000 kW
0.583 kWh
0.000 kW
2.915 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.280 0.573 1.875 9.598
09 - 202217****** IQ7+ [5] VCOP 0.000 0.281 0.578 1.893 9.695
10 - 202244****** IQ7+M [5] VCOP 0.000 0.285 0.596 1.920 9.923
11 - 202224****** IQ7+M [5] VCOP 0.000 0.285 0.593 1.935 9.998
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.285 0.617 2.201 11.169 0.000 kW
0.621 kWh
0.000 kW
2.485 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.283 0.614 2.114 10.854
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 0.632 2.192 11.212
15 - 202245****** IQ7+M [5] VCOP 0.000 0.284 0.623 2.155 11.031
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.71 V Current/Power -1.47 A (-77 W)
Remain Capacity/Energy 305.4 Ah (15.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 50.9 % State Of Health 100.0 %
Run Time 8d 15h 46m to empty Report Date 2022-06-27 23:55
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.