Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
---|
Importing from grid by 0.252 kW | |||
---|---|---|---|
01/26/2025 07:23 (1705 days) | Production | Consumption | NET Usage |
Now | 0.000 kW | 0.252 kW | 0.252 kW |
Today | 0.000 kWh (0.000 kW) | 0.977 kWh (0.132 kW) | 0.977 kWh (0.132 kW) |
- This Week | 0.000 kWh (0.000 kWh/day) | 0.977 kWh (3.166 kWh/day) | 0.977 kWh (3.166 kWh/day) |
- This Month | 194.806 kWh (7.697 kWh/day) | 580.691 kWh (22.945 kWh/day) | 385.885 kWh (15.247 kWh/day) |
- This Year | 0.195 MWh (7.697 kWh/day) | 0.581 MWh (22.945 kWh/day) | 0.386 MWh (15.247 kWh/day) |
Yesterday | 6.104 kWh (0.254 kW) | 14.029 kWh (0.585 kW) | 7.925 kWh (0.330 kW) |
Last 7 Days | 19.035 kWh (2.719 kWh/day) | 111.838 kWh (15.977 kWh/day) | 92.803 kWh (13.258 kWh/day) |
Last 30 Days | 237.946 kWh (7.931 kWh/day) | 728.406 kWh (24.280 kWh/day) | 490.460 kWh (16.348 kWh/day) |
Last One Year | 6.753 MWh (18.502 kWh/day) | 6.392 MWh (17.512 kWh/day) | -0.361 MWh (-0.990 kWh/day) |
Lifetime Since PTO | 29.646 MWh (17.384 kW/day) | 32.533 MWh (19.077 kW/day) | 2.888 MWh (1.693 kW/day) |
Lifetime Since Install | 29.680 MWh | 33.113 MWh | 3.434 MWh |
Voltage/Current | 251.0 V / 0.0 A | 251.0 V / 1.0 A | 251.0 V / 1.0 A |
Micro-inverters | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Recent Report Data/Time | 07/11/2021 23:26 (14.3 hours) | Number of Devices | 16 set | |||||||
Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 12.461 kWh | |||||||
Group | Serial Number | Model | Status | Power (kW) [Flag] | Energy (kWh) [Monthly] | Group | ||||
Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
porch | 01 - 202232127871 | IQ7+ | ---- | 0.000 | 0.281 | 0.871 | 1.180 | 10.998 | 0.000 kW 0.859 kWh |
0.000 kW 5.153 kWh |
02 - 202244177619 | IQ7+M | ---- | 0.000 | 0.276 | 0.846 | 1.142 | 10.563 | |||
03 - 202224101754 | IQ7+M | ---- | 0.000 | 0.286 | 0.874 | 1.173 | 10.694 | |||
04 - 202232127100 | IQ7+ | ---- | 0.000 | 0.285 | 0.871 | 1.167 | 10.746 | |||
05 - 202244171601 | IQ7+M | ---- | 0.000 | 0.279 | 0.844 | 1.124 | 9.912 | |||
06 - 202245013024 | IQ7+M | V--- | 0.000 | 0.277 | 0.848 | 1.143 | 10.654 | |||
front | 07 - 202206091803 | IQ7+ | -C-- | 0.000 | 0.286 | 0.839 | 1.107 | 9.878 | 0.000 kW 0.845 kWh |
0.000 kW 4.225 kWh |
08 - 202245013989 | IQ7+M | VC-- | 0.000 | 0.288 | 0.838 | 1.104 | 9.970 | |||
09 - 202217001404 | IQ7+ | VC-- | 0.000 | 0.289 | 0.846 | 1.113 | 9.990 | |||
10 - 202244165234 | IQ7+M | VC-- | 0.000 | 0.286 | 0.852 | 1.123 | 10.098 | |||
11 - 202224104308 | IQ7+M | VC-- | 0.000 | 0.286 | 0.850 | 1.122 | 10.084 | |||
back | 12 - 202211186551 | IQ7+ | ---- | 0.000 | 0.222 | 0.769 | 1.113 | 10.869 | 0.000 kW 0.771 kWh |
0.000 kW 3.083 kWh |
13 - 202223042463 | IQ7+ | ---- | 0.000 | 0.218 | 0.752 | 1.093 | 10.622 | |||
14 - 202216155993 | IQ7+ | ---- | 0.000 | 0.228 | 0.787 | 1.128 | 10.870 | |||
15 - 202245015670 | IQ7+M | ---- | 0.000 | 0.224 | 0.775 | 1.113 | 10.794 | |||
wind | 16 - 122214035120 | IQ7PD | ---- | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
Battery History | |||
---|---|---|---|
Voltage | 53.12 V | Current/Power | -1.80 A (-95 W) |
Remain Capacity/Energy | 449.4 Ah (23.0 kWh) | Full Capacity/Energy | 600.0 Ah (30.7 kWh) |
State Of Charge | 74.9 % | State Of Health | 100.0 % |
Run Time | 10d 9h 40m to empty | Report Date | 2021-07-11 23:58 |
Voltage | 53.16 V | Cell (MIN/MAX) | 3.316 V / 3.326 V (0.010 V) |
---|---|---|---|
Current/Power | -0.60 A (-31 W) | Runtime | 10d 9h 40m to empty |
Remain Capacity/Energy | 149.8 Ah (7.7 kWh) | Full Capacity/Energy | 200.0 Ah (10.2 kWh) |
State Of Charge | 74.9 % | State Of Health | 100.0 % |
Temperature | 24.5 °C | Cycle | 41 |
MOSFET | CFET = ON, DFET = ON | Reported | 2021-07-11 23:58 |